►The installation must always be secured with a secondary safety attachment, e.g. an appropriate safety
rope.Never stand directly below the device when mounting, removing or servicing the fixture.
►The operator has to make sure the safety relating and machine technical installations are approved
by an expert before taking the device into operation for the first time.
►These installations have to be approved by a skilled person once a year.
►Overhead mounting requires extensive experience, including amougst others calculating working load limits,
installation material being used, and periodic safety inspection of all installation material and the device. If you
lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily
injury.
Ringing
Insert the quick-lock fasteners of the first holder into the respective holes on the bottom of the device.Tighten
the quick-lock fasteners fully clockwise.
Make the finished installed mounting bracket tighten on the fixed bracket.
Pull the safety rope through the holes on the bottom of the base and over the trussing system or other safe
fixation spot.
Note:This step is quite important to ensure that fixture will not drop out by the damage of clamp.
4.DMX-512 control connection
Connect the provided XLR cable to the male 3-pin XLR output of your controller and the other side to the
female 3-pin XLR input of the light.You can chain multiple lights together through serial linking
The cable needed should be two core, screened cable with XLR input and output connectors. Please refer to the
diagram below.
Mounting bracket
Handing bracket
Safety-rope
Rapid locking
hook