Notice:

Be sure to follow the diagrams below when making your own cables.  
Do not connect the cables shield conductor to the ground lug or  
allow the shield conductor to come in contact with the XLRs  
outer casing. Grounding the shield could cause a short circuit  
and erratic behaviour.

 

Line termination:

When longer runs of cable are used,  
you may need to use a terminator on  
the last unit to avoid erratic behaviour.

Using a cable terminator will decrease  
the possibilities of erratic behaviour. 
(3-pin - Order ref: CABL90,  
5-pin - Order ref: CABL89)

5-pin XLR DMX connectors:

Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-pin XLR fixtures 
may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a 
3-pin line a cable adaptor must be used. The diagram below details the correct cable conversion.

5-pin XLR (female)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

Pin 4: N/C

Pin 5: N/C

3-pin XLR (female)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

3-pin XLR (male)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

5-pin XLR (male)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

Pin 4: N/C

Pin 5: N/C

DMX setup

Termination reduces signal 

transmission problems and 

interference. It is always 

advisable to connect a DMX 

terminal, (resistance 120 

Ohm 1/4W) between pin 2 

(DMX-) and pin 3 (DMX+) of 

the last fixture.

5-Pin

1

2

4

5

3

3-Pin

1

2

3

Pin Configuration

3-Pin

5-Pin

Pin 1 - Ground

Pin 2 - Negative

Pin 3 - Positive

Pin 4 - N/C

Pin 5 - N/C

1

2

3

1

2

3

DMX 512

3-Pin XLR output

DMX 512

3-Pin XLR input

GROUND

DMX +

DMX –

DMX 512

5-Pin XLR output

DMX 512

5-Pin XLR input

1

2
4 5

3

1 2

4

5

3

GROUND

N/C

DMX –

N/C

DMX +

1 ground

3 hot

2 cold

3-Pin XLR male

3-Pin XLR female

2 cold

3 hot

1 ground

2 cold

1 ground

5 N/C

3 hot

4 N/C

5-Pin XLR male

5-Pin XLR female

4 N/C

5 N/C

1 ground

3 hot

2 cold

Summary of Contents for PRO LED Starcloths CW Series

Page 1: ...Order codes 6 x 4m Black Starcloth STAR41 9 x 4m Black Starcloth STAR42 7 x 5m Black Starcloth STAR43 Starcloth Controller STAR24 PRO LED Starcloths CW User Manual...

Page 2: ...quids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Mak...

Page 3: ...with LCD display PowerCON input 3 Pin XLR input output 5 Pin XLR input output PRO Starcloths CW Specifications Power supply 100 250V 50 60Hz Fuse F2A 250V Dimensions 6 x 4m STAR41 9 x 4m STAR42 7 x 5m...

Page 4: ...N input 07 On off switch 08 Fuse F2A 250V 09 Fuse curtain 1 10 Fuse curtain 2 11 Data output 1 12 Data output 2 13 Mic 14 3 Pin DMX input 15 3 Pin DMX output 16 5 Pin DMX input 17 5 Pin DMX output 02...

Page 5: ...mes in either of the selected sound or auto modes Press the ENTER button twice to adjust the macro steps from 1 62 using the UP DOWN buttons Press the ENTER button to save your setting DMX mode To acc...

Page 6: ...buttons to select either AUTO or SOUND Press the ENTER button to save your setting Clear display mode In this mode you can have the LCD display to slowly fade out slowly or to stay on constantly To en...

Page 7: ...e for per session and total time To enter this mode press the SET ESC button to show MACHINE TIMER on the LCD display Now press the ENTER button and use the UP DOWN buttons to scroll through the time...

Page 8: ...7 dimmer 0 100 10 000 255 Group 8 dimmer 0 100 11 000 049 No function 050 059 Manual dimming mode 060 069 Program 1 070 079 Program 2 080 089 Program 3 090 099 Program 4 100 109 Program 5 110 119 Pro...

Page 9: ...ng all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data tran...

Page 10: ...cable adaptor must be used The diagram below details the correct cable conversion 5 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 pin XLR female Pin 1 GND screen Pin...

Page 11: ...rm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources...

Page 12: ...www prolight co uk PRO LED Starcloths CW User Manual 12...

Reviews: