background image

www.prolight.co.uk

Mood Bar

  

User Manual

2

Safety advice

WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL  
CAREFULLY BEFORE YOUR INITIAL START-UP!

•  Before your initial start-up, please make sure that there is no damage caused during transportation.
•  Should there be any damage, consult your dealer and do not use the equipment.
•  To maintain the equipment in good working condition and to ensure safe operation, it is necessary  

for the user to follow the safety instructions and warning notes written in this manual.

•  Please note that damages caused by user modifications to this equipment are not subject to warranty.

IMPORTANT:

The manufacturer will not accept liability for any resulting damages caused by the non-observance  
of this manual or any unauthorised modification to the equipment.

OPERATING DETERMINATIONS

If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and  
the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc. 
Do not endanger your own safety and the safety of others! 
Incorrect installation or use can cause serious damage to people and/or property.

CAUTION!

KEEP THIS EQUIPMENT 

AWAY FROM RAIN,  

MOISTURE AND LIQUIDS

CAUTION!  

TAKE CARE USING  

THIS EQUIPMENT!
HIGH VOLTAGE-RISK  

OF ELECTRIC SHOCK!!

•  Never let the power cable come into contact with other 

cables. Handle the power cable and all mains voltage  
connections with particular caution!

•  Never remove warning or informative labels from the unit.
•  Do not open the equipment and do not modify the unit.
•  Do not connect this equipment to a dimmer pack.
•  Do not switch the equipment on and off in short intervals, 

as this will reduce the system’s life.

•  Only use the equipment indoors.
•  Do not expose to flammable sources, liquids or gases.
•  Always disconnect the power from the mains when  

equipment is not in use or before cleaning! Only handle 
the power-cable by the plug. Never pull out the plug by 
pulling the power-cable.

•  Make sure that the available mains supply voltage is 

between 100~240V AC, 50/60Hz.

•  Make sure that the power cable is never crimped or  

damaged. Check the equipment and the power cable 
periodically.

•  If the equipment is dropped or damaged, disconnect the 

mains power supply immediately and have a qualified 
engineer inspect the equipment before operating again. 
 

•  If the equipment has been exposed to drastic  

temperature fluctuation (e.g. after transportation),  
do not connect power or switch it on immediately.  
The arising condensation might damage the equipment. 
Leave the equipment switched off until it has reached 
room temperature.

•  If your product fails to function correctly, stop use 

immediately. Pack the unit securely (preferably in the  
original packing material), and return it to your Pro Light 
dealer for service.

•  Only use fuses of same type and rating.
•  Repairs, servicing and power connection must only be  

carried out by a qualified technician. THIS UNIT CONTAINS 
NO USER SERVICEABLE PARTS.

•  This lighting fixture is for professional use only - it is 

not designed for or suitable for household use. The 
product must be installed by a qualified technician in 
accordance with local territory regulations. The safety of 
the installation is the responsibility of the installer. The 
fixture presents risks of severe injury or death due to fire 
hazards, electric shock and falls.

•  Warning! Risk Group 2 LED product according to 

EN 62471. Do not view the light output with optical 
instruments or any device that may concentrate the beam.

•  WARRANTY: One year from date of purchase.

Summary of Contents for Mood Bar

Page 1: ...Order code LEDJ459 Mood Bar User Manual ...

Page 2: ...hort intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available mains supply voltage is between 100 240V AC 50 60Hz M...

Page 3: ...ar away from any flammable materials and or liquids The fixture must be fixed at least 50cm from surrounding walls The device should be installed out of reach of people and outside areas where persons may walk by or be seated Before rigging make sure that the installation area can hold a minimum point load of 10 times the device s weight Always use a certified safety cable that can hold 12 times t...

Page 4: ... effects available from this compact unit Several different installation options and brackets are included along with a flip out stand for fast set up if being used by mobile entertainers Mood Bar 230mm 371mm 1605mm 106mm 112 tri colour SMD 5050 LEDs RGB Viewing angle 120 DMX channels 7 or 25 selectable Auto sound active and master slave modes 0 100 dimming and variable strobe Brackets allow for m...

Page 5: ...Fuse F1A 250V 09 Floor standing bracket 10 Mounting brackets In the box 1 x fixture 1 x PowerCON cable 1 x user manual POWER INPUT 100 240V 50 60Hz POWER OUTPUT 100 240V 50 60Hz 3 PIN DMX OUTPUT 3 PIN DMX INPUT FUSE F1A 250V MENU UP DOWN ENTER www prolight co uk MOOD BAR 01 02 03 06 04 08 07 05 09 10 10 MENU UP DOWN ENTER www prolight co uk MOOD BAR MENU UP DOWN ENTER www prolight co uk MOOD BAR ...

Page 6: ...MX address settings C H 0 7 C H 2 5 N o d E DMX channel settings S P 0 1 S p 9 9 A u t o Auto mode S U 0 1 S U 0 8 S o U n Sound mode S N 0 0 S N 9 9 S e N S Sound sensitivity setting C O 0 0 C O 0 6 C o L o Static colour mode r g b r 0 0 0 r 2 5 5 g 0 0 0 g 2 5 5 Colour mix mode b 0 0 0 b 2 5 5 ...

Page 7: ...und mode 3 222 228 Sound mode 4 229 235 Sound mode 5 236 240 Sound mode 6 241 247 Sound mode 7 248 255 Sound mode 8 7 000 255 Auto speed adjustment slow fast 7 channel mode Channel Value Function 1 000 255 Master dimmer 0 100 2 000 255 Strobe slow fast 3 000 255 Red segment 1 dimmer 0 100 4 000 255 Green segment 1 dimmer 0 100 5 000 255 Blue segment 1 dimmer 0 100 6 000 255 Red segment 2 dimmer 0 ...

Page 8: ...eNs on the LED display Press the ENTER button and then use the UP and DOWN buttons to select any value from SN00 SN99 Press the ENTER button to confirm the setting To exit out of any of the above options press the MENU button Static colour mode To access the Static colour mode press the MENU button and use the UP and DOWN buttons on the rear of the unit to show CoLo on the LED display Press the EN...

Page 9: ... is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing ...

Page 10: ...pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion Termination reduces signal transmission problems and interference It is always advis...

Page 11: ...le harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally saf...

Page 12: ...www prolight co uk Mood Bar User Manual 12 ...

Reviews: