background image

GENERAL DESCRIPTION

LedBruk Luminous Paving Stone LED is designated to
lighting the paver, building elevation or greenery.
LedBruk based on an original Cree diodes installed in
tight cover made of contruction resin. The Luminous
Paving Stone LED has airtightness IP67. In the base
version LedBruk is equipped with RGB diodes or
monochrome versions (warm white, cold white) with a
120 degree illumination angle.
For unique decorative and lighting effects the
luminaire occurs in the RGB+W version (RGB with
additional monochrome diodes). Depends of appliance
are available LED 12 V drivers and 12 V power supplies
for cooperation with the paver.

SAFETY CONDITIONS

Warning! Before installing, connecting, using and
servicing, it is imperative read this document.

LedBruk luminaire is a device powered with 12V safe
voltage, but during its installation and use it is
imperative to follow the rules given below:

1.

Installation of the luminaire should be done by a
person

with

appropriate

permissions,

as

described in the instructions.

2.

The device may only be connected to controllers
and

power

supplies

suggested

by

the

manufacturer. Using the accessories suggested by
the manufacturer LedBruk, the warranty is
extended from standard 24 to 48 months
(Accessories included in the current Price List
LedBruk Sp. z o.o.)

3.

All wires must be protected against mechanical
and thermal damage.

4.

If any of the wires are damaged, it must be
replaced with wires with the same technical data
and approvals.

5.

All repairs may only be done with power
disconnected.

6.

Wait 5 minutes after switching off the device
before carrying out any servicing.

7.

Do not connect the device with visible damage to
the power supply.

8.

Avoid sudden shocks, especially dropouts.

9.

The device can be installed and used in
accordance with the conditions contained in this
manual, as well as applicable standards and
regulations not mentioned in this document.

METHOD OF MARKING THE TYPE OF 
LUMINAIRES

002/RGB – luminaire in a RGB multicolor version
002/RGBW/BC – luminaire in a RGB multicolor version
with additional warm white LEDs in the range from
2700-3300 K
002/RGBW/BZ – luminaire in a RGB multicolor version
with additional cold white LEDs in the range from
5000-7000 K
002/BC – monochrome warm white luminaire

2700 - 3300K

002/BZ – monochrome cold white luminaire

5000 - 7000K

002 – product catalog number
RGB – multicolor version R (red) G (green) B (blue)
RGBW –multicolor version

with additional warm

white (BC) or cold white (BZ) LEDs

SETUP - DISMANTLING THE LUMINAIRES  RGB luminaire installation

We should start installing the luminaire by placing a dedicated installation wire in the ballast of a paving block, in
a place where the wire will not be exposed to mechanical damage. The picture below shows an example of the
wire routing. The luminaires are powered by a stabilized 12V voltage –to avoid voltage drops on connections and
on the wire, we suggest looping / returning to a controller or dimmer.

ul. Warynskiego 29A
05-200 Wolomin POLAND
tel. 22 350 76 36
www.ledbruk.com   
[email protected]

User manual

LEDBRUK Luminous Paving Stone LED

type RGB / RGB+W / W

1

Summary of Contents for Luminous Paving Stone LED

Page 1: ...me technical data and approvals 5 All repairs may only be done with power disconnected 6 Wait 5 minutes after switching off the device before carrying out any servicing 7 Do not connect the device wit...

Page 2: ...le in current LedBruk Price list Using dedicated installation wire entitles to receive an extended warranty of 48 months RGB version dedicated wire PDZ RGB LedBruk 4 1 0 mm2 W monochrome white version...

Page 3: ...gaskets in the gland LedBruk luminaires are connected in parallel via WAGO connectors picture below 4 Visualization of the matching of the suggested wires to the appropriate versions of the fittings R...

Page 4: ...ce the screws in the holes and tighten them photo2 photo 1 ATTENTION The tightness of the luminaire depends on the precise seating of the sealing oring while tightening the box cover special care shou...

Page 5: ...on the ballast can not be condensing with a mechanical compactor The luminaire should also not be placed directly on the dry mortar so that its possible servicing If classic paving stones are setting...

Page 6: ...n the ballast after leveling and condensing the ground under the paving stones 2 Installation of luminaires after condensing the pavement connecting the power supply with the controller or LED dimmer...

Page 7: ...upply with the controller or LED dimmer ATTENTION Before setup or dismantling the LedBruk luminaires turn off the controller s power supply In the case of monochrome luminaires white light polarity re...

Page 8: ...tion of luminaires after condensing the pavement connecting the power supply with the controller or LED dimmer ATTENTION Before setup or dismantling the LedBruk luminaires turn off the controller s po...

Reviews: