User manual
LEDBRUK Luminous Paving Stone LED
type RGB / RGB+W / W
4
SETUP- DISMANTLING THE LUMINAIRES RGB luminaire installation
5.
After connecting all internal strands via WAGO connectors, we put them in a hermetic box paying
attention to the connection of cables. We remove the reserve of wires from the interior of the box by pulling
out the wire through the gland [photo1] remembering that the black cover of the ground wire stays in the
gland leans on the gland gasket.
Next, the box cover oring must be placed in the box socket, taking care of its precise seating. Then place the
screws in the holes and tighten them [photo2].
[photo 1]
!
ATTENTION
The tightness of the luminaire depends on the precise seating of the sealing oring, while tightening the box
cover, special care should be taken to ensure that the oring is adhere with the cover of the luminaire. The
screws are tightened by using the diagonal method.
[photo 2]
6.
The screwing of the wire gland PG11 nuts remains for the final sealing of the luminaire [photo3]. To
tighten the nuts, we need the spanner No. 21. The nut should be tightened until the gasket is clamp in the
gland on the PDZ-RGBW LedBruk ground wire that prevents it from being pulled out of the gland.
[photo3]
[correctly
connected
luminaire]
ul. Warynskiego 29A
05-200 Wolomin POLAND
tel. 22 350 76 36
www.ledbruk.com
[email protected]