Operating Frequencies: 470.000 - 691.175
Frequency Selection
Steps: 25 kHz
RF Power Output:
50 mW
Frequency Stability:
± 0.002%
Digital Modulation:
8 PSK
Spurious Radiation:
>90 dB below carrier
Equivalent Input Noise: –128 dBV
Input Level:
Nominal 2 mV to 300 mV, before limiting
Greater than 1V maximum, with limiting.
Input Impedance:
• Mic: 300 Ohm
• Line: 2k Ohm
Input Limiter:
Dual envelope type; 30 dB range
Gain Control Range:
44 dB in 1 dB steps; digital control
Modulation Indicators: • Dual bicolor LEDs indicate modulation of
-20, -10, 0 and +10 dB referenced to full
modulation
• LCD bar graph
Controls:
• Top panel toggle switch; programmable as
power, mute or none (off) function
• Side panel membrane switches with LCD
interface for power on/off and all setup and
configuration controls
Audio Input Jack:
Switchcraft 5-pin locking (TA5F)
Antenna:
Galvanized steel, flexible wire
Battery:
Two AA Duracell Quantum recommended
Battery Life:
5 hours; Duracell Quantum alkaline
Weight:
6.24 ounces (177 grams), including two AA
batteries and wire belt clip
Dimensions:
3.2 x 2.5 x .74 in. (86 x 62 x 19 mm)
Emission Designator: 200KG1E
Specifications and Features
Audio Performance (Digital Hybrid mode)
Frequency Response:
Mic input:
35 Hz to 20 kHz (+/-1dB); low frequency
roll-off is selectable at 35, 50, 70, 100, 120,
180 Hz
Line/Instrument: 35 Hz to 20 kHz (+/-1dB)
THD:
0.2% (typical)
SNR at receiver output:
Note: The dual envelope “soft”
limiter provides exceptionally good
handling of transients using variable
attack and release time constants. Once activated, the limiter compresses 30+ dB
of transmitter input range into 4.5 dB of receiver output range, thus reducing the
measured figure for
SNR without limiting
by 4.5 dB
SmartNR
No Limiting
w/Limiting
OFF 103.5 108.0
NORMAL 107.0
111.5
FULL 108.5 113.0
Specifications subject to change without notice.
For body worn operation, this transmitter model has been tested and meets the FCC RF exposure
guidelines when used with the Lectrosonics accessories supplied or designated for this product. Use of
other accessories may not ensure compliance with FCC RF exposure guidelines. Contact Lectrosonics
if you have any questions or need more information about RF exposure using this product..
This device complies with FCC radiation exposure limits as set forth for an uncontrolled environment.
This device should be installed and operated so that its antenna(s) are not co-located or operating in
conjunction with any other antenna or transmitter.
This device complies with Industry Canada radiation exposure limits as set forth for a controlled
“professional” use only.
Cet appareil est conforme avec les normes d’Industrie Canada concernant les limites d’exposition aux
radiations pour un usage professionnel contrôlé seulement.