13
INSTALLATION MENU
The installation menu contains settings that are usually set up at the same time as
the system. The menu has the following structure.
Network
WiFi
Determines whether WiFi has been activated.
Enabled/
Disabled
WiFi network
Finds and lists available WiFi networks. Select the
network and give the password using arrows.
Confirm the password by pressing the right arrow
three times.
Cloud PIN
Request a PIN code to connect to your Cloud
account. The code will be valid for 15 minute or
until a new code is requested.
Valve handling
Conditioning
Determines whether Maintenance has been
activated. If ”Disabled” is selected, maintenance
will not be performed automatically.
Enabled/
Disabled
Time of day
Indicated the time of the day when maintenance will
be performed.
00:00-23:59
(04:00)
Sensor diag.
Automatic sensor test. If there hasn’t been any pulse
registered in the last seven days, a warning is given.
Enabled/
Disabled
Input handling
AUX1 in
Indicates whether you prefer to switch between
the Home mode and the Away mode with a separate
button or with the burglar alarm. In other cases,
the input can be set to rise a warning or an alarm
from an external device, i.e. moisture sensor,
thermostat or pressure sensor. If a pulse water meter
is connected to the input, the water consumption
can be calculated. If ”Disabled”, no activity will be
registered through this input.
Disabled/
Water meter/
Home/
Away/
Warning/
Alarm
AUX1 active
Indicates whether the input will be activated when it
is high or low.
High/Low
The settings below are only visible when the AUX1 in input is configured as water meter.
AUX1 pulse unit
Specify the unit that is intended for the set value,
pulse size. This value must be set according to the
connected water meter’s technical specifications.
liter/puls,
puls/liter
AUX1 pulse size
Specify the quantity of water to which each pulse
from the water meter is equivalent. This value must
be set according to the connected water meter’s
technical specifications.
1-1000 (10)