5. REMOTE CONTROL
13
No. 8
Command ALV
Description
Get the audio level
Notes
Retrieves the maximum and minimum levels over the last 200 ms.
For stereo input, values for channels other than channels 0 and 1 are void.
Data
Description
Format
1
0 to 65535
Channel 0 maximum level
DEC
2
0 to 65535
Channel 2 maximum level
DEC
3
0 to 65535
Channel 4 maximum level
DEC
4
0 to 65535
Channel 1 maximum level
DEC
5
0 to 65535
Channel 3 maximum level
DEC
6
0 to 65535
Channel 5 maximum level
DEC
7
0 to 65535
Channel 0 minimum level
DEC
8
0 to 65535
Channel 2 minimum level
DEC
9
0 to 65535
Channel 4 minimum level
DEC
10 0 to 65535
Channel 1 minimum level
DEC
11 0 to 65535
Channel 3 minimum level
DEC
Rsp. parameter
12 0 to 65535
Channel 5 minimum level
DEC
No. 9
Command APP
Description
Get the audio amplitude level
Notes
Retrieves the maximum and minimum amplitude levels over the last 200 ms.
For stereo input, values for channels other than channels 0 and 1 are void.
Data
Description
Format
1
0 to 65535
Channel 0 amplitude maximum level
DEC
2
0 to 65535
Channel 2 amplitude maximum level
DEC
3
0 to 65535
Channel 4 amplitude maximum level
DEC
4
0 to 65535
Channel 1 amplitude maximum level
DEC
5
0 to 65535
Channel 3 amplitude maximum level
DEC
6
0 to 65535
Channel 5 amplitude maximum level
DEC
7
0 to 65535
Channel 0 minimum maximum level
DEC
8
0 to 65535
Channel 2 minimum maximum level
DEC
9
0 to 65535
Channel 4 minimum maximum level
DEC
10 0 to 65535
Channel 1 minimum maximum level
DEC
11 0 to 65535
Channel 3 minimum maximum level
DEC
Rsp. parameter
12 0 to 65535
Channel 5 minimum maximum level
DEC