Leader LT 6280A Instruction Manual Download Page 1

 

 

 

 

 
 
 
 

 

 
 
 
 
 

LT 6280A 

HDMI SOURCE DEVICE CHECKER 

 
 

INSTRUCTION MANUAL 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

Summary of Contents for LT 6280A

Page 1: ...LT 6280A HDMI SOURCE DEVICE CHECKER INSTRUCTION MANUAL...

Page 2: ...2 SPECIFICATIONS 2 2 1 Description 2 2 2 Features 2 2 3 Specifications 3 2 3 1 HDMI Input 3 2 3 2 External Interface 3 2 3 3 Features 3 2 3 4 General Specifications 4 3 PANEL DESCRIPTION 5 3 1 Front...

Page 3: ...tand If you have any questions about the contents of this manual please contact your local LEADER agent Symbols and Terms The following symbols and terms are used in this instruction manual and on the...

Page 4: ...that the instrument has condensation within it wait for approximately 30 minutes before turning on the power Operating Humidity Range Use this instrument in an environment whose relative humidity is...

Page 5: ...er outlet do not pull on the cord Pull from the plug Warnings Concerning Grounding The instrument has a ground terminal to protect the user and the instrument from electric shock Ensure that the produ...

Page 6: ...with mild detergent and wipe gently While cleaning make sure that foreign materials such as water and detergent do not enter the instrument If liquid or a metal object enters into the instrument fire...

Page 7: ...een improperly repaired adjusted or modified by personnel other than a factory trained LEADER representative 3 Repair of malfunctions or damages resulting from improper use 4 Repair of malfunctions ca...

Page 8: ...the comparison result and the number of mismatched data points or the mismatched data positions to a PC Audio Data Checking The LT 6280A can send the output level of the audio data that is being recei...

Page 9: ...3 3 Features Video Data Checking Compares received video data with reference data Sends the comparison result and the number of mismatched data points or the mismatched data positions to a PC TMDS Inp...

Page 10: ...on Optimal Temperature 10 to 35 C Operating Environment Indoors Elevation Up to 2 000 m Overvoltage Category II Pollution Degree 2 Power Requirements Voltage 90 to 250 VAC Frequency 50 60 Hz Power Con...

Page 11: ...n be turned on and off remotely 3 POWER Lights when the power is on 3 2 Rear Panel No Name Description 1 Fan Cooling fan 2 Ground terminal Connect to an external ground 3 HDMI Connect to an HDMI sourc...

Page 12: ...e operation of the HDMI source device For information on remote control see the next chapter 4 2 Turning the Power On When you turn on the LT 6280A the STATUS LED changes as shown below It takes 30 se...

Page 13: ...1 Space Tx parameter 2 CR Response Messages The number of parameters varies depending on the response Some responses do not have any parameters If there is an error in a transmission command the LT 62...

Page 14: ...image and saves it Response SIF test bmp 1280 720 8 Successful save operation Comparison Using the image data saved in Preparation as a reference compare images Send RID Retrieves the image to compare...

Page 15: ...e HDCP authentication status 13 HEC Clear the number of HDCP errors 14 HAC Clear the number of HDCP authentication completions 15 RHD Get the HDCP data 16 RPT Set the HDCP operation mode 17 CRI Clear...

Page 16: ...C Tx parameter can be omitted 1 1 Get Rsp parameters 1 to 13 DEC 1 0 1 Same as the Tx parameters DEC 2 0 to 1920 Image data width DEC 3 0 to 1470 Image data height DEC 0 Progressive DEC 4 1 Interlace...

Page 17: ...essary Data Description Format 0 when omitted Left image DEC Tx parameter can be omitted 1 1 Right image DEC 1 0 or 1 Same as the Tx parameters DEC 2 0 to 1920 Image data width DEC 3 0 to 1080 Image d...

Page 18: ...o 12 Number of color bits in the image data DEC No 7 Command CMP Description Compare the image data Notes Compares the image data retrieved using RID and that loaded using LIF For example addresses wh...

Page 19: ...ter 12 0 to 65535 Channel 5 minimum level DEC No 9 Command APP Description Get the audio amplitude level Notes Retrieves the maximum and minimum amplitude levels over the last 200 ms For stereo input...

Page 20: ...5 other DEC 6 GBD DEC Tx parameter can be omitted 1 7 VSI DEC 1 0 to 7 Same as the Tx parameters DEC Rsp parameter 2 Up to 32 bytes InfoFrame data HEX No 12 Command HDS Description Get the HDCP authen...

Page 21: ...Format 0 when omitted Sink mode DEC Tx parameter can be omitted 1 1 Repeater mode DEC Rsp parameter 1 0 or 1 Same as the Tx parameters DEC No 17 Command CRI Description Clear the HDCP Ri No 18 Comman...

Page 22: ...Notes If there is no received data Rsp parameters 1 to 3 will not be returned Data Description Format 1 00 to FF Transmission header The higher 4 bits are the HDMI source device address The lower 4 bi...

Page 23: ...parameter can be omitted 4 Gateway STR 1 0 or 1 Same as Tx parameter 1 DEC 2 Same as Tx parameter 2 STR 3 Same as Tx parameter 3 STR Rsp parameter 4 Same as Tx parameter 4 STR No 27 Command INT Descr...

Page 24: ...9 Command VER Description Get the version information Data Description Format 1 00000000 to 99999999 Application version DEC 2 00000000 to 99999999 Sub microprocessor version DEC Rsp parameter 3 0000...

Page 25: ...eness accuracy and effectiveness of it About the Sample Software Application If you run LT6280A_Remote_Sample exe the following screen will appear You can use the screen to remotely control the LT 628...

Page 26: ...Following information is for Chinese RoHS only LT 6280A 2006 2 28 SJ T11364 2006 Hazardous Substances in each Part Parts Pb Hg Cd Cr PBB PBDE SJ T11363 2006 SJ T11363 2006 Ver 1...

Page 27: ...LEADER ELECTRONICS CORP 2 6 33 Tsunashima Higashi Kohoku ku Yokohama 223 8505 Japan PHONE 81 45 541 2123 FAX 81 45 541 2823 http www leader co jp May 11 2012 Ver 1 FW Ver 3 0...

Reviews: