background image

 

 

4  DESCRIPTION 

 

 

Standard handle nozzle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TriggerFlow nozzle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hard anodized 

aluminium body 

Grab handle 

Rotating input 

connector 

Flow selector ring 

Machined aluminium 

gear teeth. 

Tactile detection of maximum 

flow 

Spray selector head with shock 

protection 

Jet Attack tactile 

flow detection 

Handle grip 

Rotating input 

connector 

Hard anodized 

aluminium body 

Opening lock button 

Input filter 

Trigger opening 

Handle grip 

Protective hoop 

Spray selector head with 

shock protection 

Summary of Contents for FLOWMATIC CFMA-0536-EI

Page 1: ...1 ...

Page 2: ...2 Product reference MULTIFLOW FLOWMATIC MULTIMATIC See models on pages 13 14 15 ...

Page 3: ...idelines must be followed in order to prevent accidents Any disassembly or repair must be performed by either LEADER or an approved dealer This manual presents the simplicity and ease of use of the nozzle In order to improve this manual LEADER remains open to your suggestions Please do not hesitate to contact us ...

Page 4: ...ULTIFLOW model 13 5 3 FLOWMATIC model 14 5 4 MULTIMATIC Model 15 6 REQUIREMENT 16 7 USING THE DEVICE 17 7 1 Implementing the standard handle nozzle 17 7 2 Implementing the TriggerFlow nozzle 18 8 FLOW RATE DIAGRAM PRESSURE 19 8 1 MULTIFLOW model 19 8 2 FLOWMATIC model 20 9 MAINTENANCE 21 10EXPLODED VIEW 21 11WARRANTY 22 ...

Page 5: ...e with pressure regulator MULTIMATIC nozzle with several pressure settings The choice between several body types Aluminium body with a standard handle Aluminium body with a trigger handle or without a protective hoop A range of colours to suit your taste Red is the default colour for MULTIFLOW nozzles Blue is the default colour for MULTIMATIC and MULTIFLOW nozzles Orange Green Yellow A choice of m...

Page 6: ...ater on the protective clothing of a team members subjected to heat radiation is prohibited Never allow someone to use the device without having provided them with the necessary instructions Do not leave water inside the gun if there is a risk of freezing Rinse with clean water after use with seawater brackish water or additive water Do not disconnect the device from the hose without first making ...

Page 7: ...NH MI 1 5 F BSP TI 1 5 F NPSH RI 1 5 F NH EI 2 M BSP R Red B Blue O Orange G Green Y Yellow TriggerFlow is only in Red FM FlowMatic 36 Ring 150 lpm 6b 37 No ring 150 lpm 6b 38 Ring 250 lpm 6b 39 No ring 250 lpm 6b 40 Ring 400 lpm 6b 41 No ring 400 lpm 6b 42 AA no ring 400 lpm 6b 43 No ring 125 gpm 100PSI 56 Ring 125 gpm 100PSI MM MultiMatic 45 Puls 125 gpm 46 Puls 400 lpm 47 Puls Low 400 lpm 48 Pu...

Page 8: ...ctor ring Machined aluminium gear teeth Tactile detection of maximum flow Spray selector head with shock protection Jet Attack tactile flow detection Handle grip Rotating input connector Hard anodized aluminium body Opening lock button Input filter Trigger opening Handle grip Protective hoop Spray selector head with shock protection ...

Page 9: ...e AGS T5 aluminium alloy construction Protection against mechanical and chemical attack by 50μ hard anodization and Teflon impregnation Protection against shocks thanks to its heat and cold resistant polyurethane head sheath Excellent thermal insulation Its ergonomic grip is made of non slip polyamide Protective hoop optional Stainless steel pins and screws Ergonomic handle Interchangeable handles...

Page 10: ...ration this enables evacuating debris that may have passed through the filter The purge can be triggered either by means of the flow ring in the FLUSH position or by rotating the head beyond the protective spray Inlet connection Rotating 360 various choices possible Female 1 BSP Female 1 NH Female 1 5 BSP Female 1 5 NH Female 1 5 NPSH Male 2 BSP Spray The spray system can be selected either with m...

Page 11: ...ing the shape of the selected spray Engravings Various models Option MULTIFLOW Adaptable spray shape with an adjustable flow By simply rotating a flow selector ring This ring has the flow rates engraved on it 20 40 100 150 lpm 70 130 230 400 lpm 5 10 24 40 gpm 30 60 95 125 gpm FLUSH This corresponds to the Flush position It is used to evacuate any debris stuck inside the device Tactile detection a...

Page 12: ...or Low and Medium 5 FEATURES 5 1 General information Manufacturer LEADER Size COMPACT Operation under nominal pressure PN 40 Type of spray Diffusion alternating between hollow cone solid cone Valve Sliding valve Protective filter Against debris at the inlet connection L h L h l l ...

Page 13: ...76 285 117 232 CMFA 0532 EI 2 M BSP 1 79 309 117 232 CMFG 1532 EI TriggerFlow Fixed 2 M BSP 2 39 356 87 209 CMFA 0752 MI 470 lpm 7 bars Aluminium Turbine 1 5 F BSP 1 03 270 117 232 CMFA 0533 1I 5 10 24 40 gpm Aluminium Fixed 1 F NH 1 74 270 117 232 CMFA 0733 1I Turbine 1 F NH 1 74 270 117 232 CMFG 1533 1I TriggerFlow Fixed 1 F NH 2 34 325 87 209 CMFG 1733 1I Turbine 1 F NH 2 38 325 87 209 CMFA 053...

Page 14: ...9 290 117 232 CFMG 1539 LI TriggerFlow Fixed 1 F BSP 2 25 306 87 209 CFMG 1539 EI 2 M BSP 2 3 337 87 209 CFMA 0540 MI 0 400 lpm 6 bar Aluminium Fixed 1 5 F BSP 1 76 285 117 232 CFMA 0540 EI 2 M BSP 1 79 309 117 232 CFMA 0541 LI Aluminium Fixed 1 F BSP 1 75 251 117 232 CFMA 0541 MI 1 5 F BSP 1 76 266 117 232 CFMA 0541 EI 2 M BSP 1 79 290 117 232 CFMG 1541 MI TriggerFlow Fixed 1 5 F BSP 2 27 321 87 ...

Page 15: ...17 232 CMMG 1547 EI TriggerFlow Fixed 2 M BSP 2 386 356 87 209 CMMA 0548 TI 125 gpm Pulsing Low Pressure Aluminium Fixed 1 5 F NPSH 1 758 285 117 232 CMMA 0548 RI 1 5 F NH 1 758 285 117 232 CMMG 1548 TI TriggerFlow Fixed 1 5 F NPSH 2 354 340 87 209 CMMG 1548 RI 1 5 F NH 2 354 340 87 209 CMMA 0549 MI 0 400 lpm Low Pressure Aluminium Fixed 1 5 F BSP 1 758 285 117 232 CMMA 0549 EI 2 M BSP 1 79 309 11...

Page 16: ...e required to operate the rotary inlet connector 1 N m EN 15182 2 4 2 3 Flow control for FLOWMATIC models Rotation from minimum flow to maximum flow 90 EN 15182 2 4 2 4 Spray adjustment Rotation from a straight spray to a wide diffusion spray with a minimum diffusion angle of 100 90 PERFORMANCE EN 15182 2 4 3 3 Effective range See Flow Pressure Curve EN 15182 2 4 3 4 Wide spray 120 EN 15182 2 4 3 ...

Page 17: ...e detection indicates the attack spray E Select the desired flow rate on the ring Tactile detection indicates the maximum flow rate G Anticipate the reactive force when initiating the device Storing the nozzle A Turn off the pressure B Turn on the device and set the position to FLUSH C Disconnect the device E Drain any water remaining inside F Check and clean the inlet filter if necessary Attack s...

Page 18: ... attack spray D Press the trigger while anticipating its reactive force E Block the trigger by pressing the lock button if necessary F Unlock by simply activating the trigger Storing the nozzle A Turn off the pressure B Release the trigger If locked apply a brief pressure to the trigger C Disconnect the device D Drain any water remaining inside E Check and clean the inlet filter if necessary Attac...

Page 19: ...19 8 FLOW RATE DIAGRAM PRESSURE Range in meters at the indicated pressure Range in feet at the indicated pressure 8 1 MULTIFLOW model 25 128 ft ...

Page 20: ...20 8 2 FLOWMATIC model ...

Page 21: ...e after each use with clear water externally and internally while under pressure In case of repeated use with sea water or brackish water it is recommended once a year to disassemble the device clean all parts and reassemble it using the maintenance procedure provided with the spare parts kit This task can be carried out at LEADER s workshops 10 EXPLODED VIEW To locate and identify the parts of yo...

Page 22: ...s attributable to LEADER the company will repair it and assume the costs thereof excluding transport and travel expenses If the defect is not attributable to LEADER see the procedures provided in the paragraph out of warranty Defect This warranty does not commit LEADER in the following cases failure due to mishandling misuse of the equipment lack of maintenance incident to the equipment repair or ...

Page 23: ...23 ...

Page 24: ...24 Package leaflet code COMPACT 00 ZN1 2 EN 1 ...

Reviews: