Portable Plasma Torch Height Controller Manual (F1620)
13
collision halt signal to CNC during
torch work.
P12
0
或
1
1
P12 1
Switching motor contrary or positive
direction of rotating. Instead of
changing wiring, changing this
parameter can change the motor
direction of rotating.
P13
0
或
1
1
P13 1
Enable the proximity switch collision
check. When user set it as 1, the
proximity switch collision check is
allowed.
P14
1-50 1
50
P14 50
Brake speed adjust step and length.
When set it as 50, brake speed is
fastest.
P15
1-100 1
100
P15 100 Speed adjust step and length when
motor turn contrary. The bigger value
can make reversal transition speed
become more and more smaller.
P16
0.1-2 0.01 0.2 P16 0.2 Unit
:
Second(S). Arc voltage delay
time of setting.
P17
0-10 0.1 1
P17 1.0 Unit
:
Second(S). The lifting time of
starting up.
P18
0.1-1
0
0.1 2 P18 2.0 Unit
:
Second(S).The time of
promoting the spear after torch have
accomplished
P19
0-9.9
9
0.01 0
P19 0
Unit
:
Second(S).Torch lifting time
when arc start start to work.
P20
0-20 0.1 6
P20 6.0 Unit
:
Second(S). The time of
descending rapidly during the dual
speed IHS.
Parameter explain particularly:
1.
P00
:
Recovering factory parameter.
P00 can display 1. If user set it as 0 and
save this parameter, all kinds of parameter in our equipment will recover factory
parameter. After user exit the submenu, they can find that P00 display 1.
2.
P01
,
P02
,
P03
,
P04
:
Setting manul lifting and auto lifting speed of torch. The
minimum speed is 0, the maximum speed is 50.
3.
P05
:
The value of promoting arc voltage.
During torch is cutting, if gun of