03.5 dMX channels - subject to change

The latest version of DMX channels appendix are on the websites  - www. leaderlight.eu

If you have any question please, contact [email protected]

180°

AIMING PoSSIBILITy

The fixture could be aim to wish position with 

adjustable bracket.

Ch.

RGBAW

AW

AWUv

Mode1: dip2=off

1

R 1, R 2, R 3

A 1, A 2, A 3

A 1, A 2, A 3

2

G 1, G 2, G 3

W 1, W 2, W 3

W 1, W 2, W 3

3

B 1, B 2, B 3

Master (Dip1=On, Dip4=Off) UV 1, UV 2, UV 3

4

A 1, A 2, A 3

Strobo (Dip1=On, Dip4=Off) Master (Dip1=On, Dip4=Off)

5

W 1, W 2, W 3

Strobo (Dip1=On, Dip4=Off)

6

Master (Dip1=On, Dip4=Off)

7

Strobo (Dip1=On, Dip4=Off)

Mode4: dip2=on

1

R 1

A 1

A 1

2

G 1

W 1

W 1

3

B 1

A 2

UV 1

4

A 1

W 2

A 2

5

W 1

A 3

W 2

6

R 2

W 3

UV 2

7

G 2

Master (Dip1=On,Dip4=Off) A 3

8

B 2

Strobo (Dip1=On, Dip4=Off) W 3

9

A 2

UV 3

10

W 2

Master (Dip1=On,Dip4=Off)

11

R 3

Strobo (Dip1=On, Dip4=Off)

12

G 3

13

B 3

14

A 3

15

W 3

16

Master (Dip1=On,Dip4=Off)

17

Strobo (Dip1=On, Dip4=Off)

Extention and control functions:

Dip4=Off, Dip1=Off =>DipBCD: use rotating switch for DMX start address 

                                                   (RS1-100, RS2-010, RS3-001) from 001 to 511
Dip4=Off, Dip1=On:                   2channels (Strobo)

Dip4=On, Dip1=Off:                   switch on AutoRun-table functions: 

                                                  “100“=Prg.0-9, “10“=StepTime, “1“=FadeTime

Dip4=On, Dip1=On:                   switch all channels on 50% - test function
Dip2=Off: Mode 1 (5+2ch)

Dip2=Off: Mode 1 (2+2ch)

Dip2=Off: Mode 1 (3+2ch)

Dip2=On: Mode 4 (15+2ch) Dip2=On: Mode 4 (6+2ch)

Dip2=On: Mode 4 (9+2ch)

Dip3=Off:                                   standard curve
Dip3=On:                                   ultraSoft curve

* Standard delivery with LL BRACKET STAGE ADJUSTABLE
** Vario Optic should be ordered separately

05 MAINTENANcE

To tackle all Safety Information- 01!

Damage caused by inadequate cleaning or maintenance is not covered by 

warranty.

Regular cleaning is demand (dust, dirt, ...).

Maintenance policy:

Unplug mains before maintenance and at least 10 minutes cool off

Appliance do not illegal open or demount 

Clean-up dust only from outer surface (for ex. scuttle, diffuser and lenses).

Use vacuum or dumpy duster (warm water)

Before reinstalling to check failure-free state – no wet parts!

-

-

-

-

-

-

-

-

Mechanical mounting of LL STAGE WASH on stage

Mounting on stage is easy using various accessories as seen below (Figures Nr. 1.1 to 1.4).  The brackets are connect by Camlocs.

It is not necessary to open the fixture for echange of Vario Optic (Figures Nr. 3.1 to 3.2).

3.2 

Carefully remove the optic modul and insert the new one and fix with screws.

1.1 Serial connection by LL36 600 for creation of continuous line

camloc 1/4 turn fasteners

Safe mechanical quick release 

fastener systems

Locking/unlocking by quarter turn 

Hand operated

Service-friendly, time-saving 

and cost cutting

Vibration-resistant 

-

-

-

-

-

1.2 Serial connection by LL36 610 for creation of line with extension

1.4 Parallel connection by triple bracket LL36 630 

1.3 Parallel connection by dual bracket LL36 620 

Mechanical mounting of tubus and frame to the LL STAGE WASH

2.1 Fit the tube LL37 300 / LL37 303 part on top of fitting. The tube screws screw into the fitting holes. 

      The tube is ready to use.

Tube and frame installation without tools (Figures Nr. 2.1 to 2.2).

2.2 The frame must be installed together with tube LL37 303. The frame mount with screws on the 

       top of tube.

3.1 The optic installation is easy and fast by 2 screws.

LL36 600

LL36 610

LL36 620

LL36 630

vario optic installation

04 PERNAMENT USE LIMITATIoNS foR HEATING dISSIPATIoN

Pernament use limitations for heating dissipation of LL STAGE WASH RGBAW  

body temperature must be less then 55°c

40°c ambient temperature  -20% of total power

30°c ambient temperature  -10% of total power

20°c ambient temperature  -0% of total power 

Black version - 30%

Silver or White version - 50%

Example: Then final pernament value for BLACK colour and 40°C ambient 

temperature = -30% -20% = 56% = max 143 ≥ (R + G + B + W +A) / 5

It‘s mean average of power go inside the fixture at DMX signal

Example:

black LL STAGE WASH: 180 ≥ (R + G + B + W + A) / 5

Silver or White LL STAGE WASH: 128 ≥ (R + G + B + W +A) / 5

value for R or G or B or W or A is 100% = 256 = 8bit levels  *** REd 50% = 128 

value, REd 75% = 192 value  

final information we don’t drop down each colour power with temperature 

control to get maximum for each colour under total recomMendations , therefore 

you need setup limitations from control desk !!! 

 

dAISy coNNEcTIoN LIMITATIoN:

6pcs 600mm LL STAGE WASH 600 or 3pcs 1200mm LL STAGE WASH 1200 is 

possible to connect by daisy chain connection

-

Reviews: