![Leader Light LL STAGE WASH 600 User Manual Download Page 1](http://html1.mh-extra.com/html/leader-light/ll-stage-wash-600/ll-stage-wash-600_user-manual_1864767001.webp)
USER MANUAL
LL STAGE WASH 600/1200/1800
Leader Light s.r.o.
M.Gorkeho 33
SK-052 01 Spisska Nova Ves
Slovakia
www.leaderlight.eu
All dimensions are in millimeters
WARNING!!!
Carefully read before installing, powering or servicing.
Nothing to do if anything misunderstand! Installation can be done only by a qualified
professional in accordance with relevant local codes.
01 SAfETy INfoRMATIoN
01.1 Risk of eyes damage
Do not look directly into LED lamps.
Do not look into light beam from a distance of less than 40 cm (16 inches)!
-
-
01.2 Protection from electric shock
Shut down power before installation or maintenance.
Luminaries and recommended AC power supply must be installed by a qualified
professional in accordance with relevant local codes. Only acceptable source of AC power
and frequency that complies with local building and electrical codes to use.
Do not use or do not connect the products if the power cable, power plug or fixtures are any
way damaged, wet, or if they are overheating.
Do not modify, alter, or attempt to service the LeaderLight appliance. Doing so will void the
warranty.
Before removing or installing any cover or part of appliance disconnect it from AC power.
Appliance always connect to earth (eltech.).
-
-
-
-
-
-
01.3 fire prevention
Follow all safety consideration.
Thermostatic switches or fuses never to bypass.
Device never shield. Around the axis of the fitting (180°) must be maintained space for
cooling. Minimum distance from the surrounding objects must be 100mm (4 in.).
LEDs never direct cover with filters or other materials.
Allowing max. ambient temperature is 40°C (104°F).
Luminaries never use without mounting brackets. The housing never install directly to the
surface.
-
-
-
-
-
-
02 PRodUcT SPEcIfIcATIoN
02.1 Technical Specification
LEd
INdIcATIoN
STATUS
POWER (Green)
blinking – 2Hz
OK - inside fixture is everything correct
DATA (Yellow)
light off
NO DMX512 signal
DATA (Yellow)
blinking – 4Hz
OK- income correct DMX512 signal
DATA (Yellow)
fast blinking
NON correct digital signal
POWER (Green)
alternate blinking
Autotest function
DATA (Yellow)
control LEds Indication
POWER
DATA
03 INSTALLATIoN
03.1 Unpacking
Unpack carefully.
This is electronic equipment and should be handled carefully.
Damaged delivered package or if are any mechanical parts broken – it must be claim
immediately by the transport company. Photo pictures as evidence are valuable for
future claim.
-
-
-
03.2 Physical installation
Loading capacity of bearing area has to be at least 10 times the weight of all device
clusters (luminaries, clamps, cables, ...).
Hairbreadth from combustible materials is 0,5m.
Before physical installation insert the optic modul on front of luminary. The optic installa-
tion is easy and fast by 2 screws. (
figures Nr. 3.1 to 3.2)
-
-
-
03.3 connecting to Ac power
To tackle all Safety Information- 01!
For protection from electric shock, the device must be grounded (earthed)!
It is not necessary to open the fixture before power supply. Power supply is solved
simple with Neutrik PowerCon connectors.
The fixture is equipped with auto-switching power supply that automatically adjusts to
any 50-60Hz AC power source from 100-260V.
Cord plug connections:
-
-
-
-
-
©MMX - Leader Light – All right reserved
02.2 Back panel
If you have any question please, contact [email protected]
coMPLIMENTS oN yoUR PURcHASE!
Symbol
Pin
Wire colour
Screw (US)
L
live
brown
yellow or brass
N
neutral
blue
silver
ground (earth)
yellow/green
green
03.4 control data connecting
Control data cable length is specified by Norm IEC929 Annex E4.
It is not necessary to open the fixture before connecting of DMX512 control signal.
Interconnections are realized by Neutrik XLR 5pin In/Out connectors.
Pin connections:
Pin 1 – ground
Pin 2 – signal negative
Pin 3 – signal positive
-
-
-
content:
01 SAfETy INfoRMATIoN
01.1 Risk of eyes damage
01.2 Protection from electric shock
01.3 Fire prevention
02 PRodUcT SPEcIfIcATIoN
02.1 Technical Specification
02.2 Back panel
03 INSTALLATIoN
03.1 Unpacking
03.2 Physical installation
03.3 Connecting to AC power
03.4 Control data connecting
03.5 DMX channels
04 PERMANENT USE ANd dAISy coNNEcTIoN LIMITATIoNS
05 MAINTENANcE
Without optic:
LL76 3xx
LL76 4xx
*
P4: R-Red, G-Green, B-Blue, A-Amber, W-White (6300°K)
- UV: UV-Ultra Violet
Dip options
Rotating DIP address 000÷511
“100“ “10“ “1“
DMX Out
XLR-5pin
DMX In
XLR-5pin
Power In
PowerCon
Power Out
PowerCon
Control LEDs
LL STAGE WASH
Made in EU
Leader Light s.r.o.
Slovakia 2009
www.leaderlight.eu
MODE ADDRESS
PoWER dATA
WARNING - Disconnect
mains before remove cover!
!
!
WARNING!!!
Non-minimum distance and/or non-use
the original brackets is at your own risk!
ENvIRoNMENT
Do not throw away the appliance with the normal household waste at the end
of its life, but hand it in at an official collection point for recycling. By doing
this, you help to preserve the environment.
!
!
WARNING!!! AWUv versions:
Overall allowable time of exposure of unprotected eyes in relation to the distance from the
light source results:
distance (m)
0,6m
1,0m
2,0m
3,0m
max. exposure time (h:m:s)
0:17:52
0:35:55
1:35:24
2:43:08
following items are included:
1. Version without Vario optic
- LL STAGE WASH with adjustable bracket
1 pc.
- PowerCon type “A“ + “B“
1 pc.
- User manual
1 pc.
2. Version with Vario optic
- LL STAGE WASH with adjustable bracket
1 pc.
- LL VARIO OPTIC WASH 600 25°
1 pc.
- PowerCon type “A“ + “B“
1 pc.
- User manual
1 pc.
Additional items needed:
- Data cables with XLR 5pin Female/Male
1 pc.
- Controller compatible with DMX
1 pc.
- Mounting accessories as necessary
Surface mounting:
- Screws and washers M12 or M10
min. 4pcs.
Lamp type
600/1200/1800mm: 66/132/198 x LED *
VarioOptic
15°, 30°, 40°, 60°, EL (20°x40°)
Control data con-
nection
DMX 512 In/Out with XLR 5pin
Power connection
AC90-264V, 47-63Hz In/Out PowerCon
Max. input power
600/1200/1800mm: 102/203/306 W
Net weight
600/1200/1800mm: 5,5/11,0/17,0 kg (12,1/24,3/37,5 lb)
Lifetime
75.000 hours (70% lumen maintenance at T
a
=+25ºC (77°F))
Ambient temp. (Ta)
Maximum 40°C (104°F)
Cooling
Conventional
Installation
Fast mounting using Camlocs
Materials and finish Powder painted anodized aluminium in RAL 9005 (other colours on
request)