Camloc 1/4 turn fasteners

Safe mechanical quick release 
fastener systems
Locking/unlocking by quarter turn 
Hand operated
Service-friendly, time-saving 
and cost cutting
Vibration-resistant 

-

-
-
-

-

Mechanical mounting of LL STAGE 6-06D

03.4 Control data connection

Control data cable length is specifi ed by Norm IEC929 Annex E4.

It is not necessary to open the fi xture before connecting of DMX512 control sig-

nal. Interconnections are realized by Neutrik XLR 5pin In/Out connectors.

Pin connections:

                            Pin 1 – ground

                            Pin 2 – signal negative

                            Pin 3 – signal positive

-

-

-

03.5 DMX channels

These informations are subject to change, latest data are on: www.leaderlight.eu 

04   MAINTENANCE AND SERVICE

Before any maintenance is necessary to carefully read all 

SAFETY INFORMATION 01!

Damages caused by inadequate cleaning or maintenance are not covered by warranty.

Requires periodic cleaning (dust, dirt ,...)

Procedure for maintenance:

Unplug mains before maintenance and at least 10 minutes cool off.

Appliance do not illegal open or demount.

Clean-up dust only from outer surface. Use vacuum or dumpy duster (warm 

water)

Before reinstalling make sure everything is intact and dry– no wet parts!

Service:

Customer service provided by the manufacturer.

-

-

-

-

-

-

-

-

!

Mechanical mounting of frame to the LL STAGE 6-06D

2.1 The screws unlock by hand. Pick out the frame.

Frame installation without tools (Figures Nr. 2.1 to 2.2).

AIMING POSSIBILITY

The fi xture could be aim to wish position with 

adjustable bracket.

Mounting on stage is easy using various accessories as seen below (Figures Nr. 1.1 to 1.2).  The brackets are connect by Camlocs.

1.1 Serial connection by LL36 300 for creation of continuous line

1.2 Parallel connection by dual bracket LL36 320 

LL36 320

LL36 300

LL37 230

LL37 220

2.2 Insert the new frame. Apply the screws by hand.

Functions Dip1-Dip4:

- Dip2=Off, Dip3=Off: Mode1: 6ch(W1,W2,W3,W4,W5,W6) +2ch(Master,Strobo)
- Dip2=Off, Dip3=On: Mode2: 1ch(W1+W2+W3+W4+W5+W6) 

+2ch(Master,Strobo)

- Dip2=On, Dip3=Off: Mode3: 2ch(W1+W3+W5, W2+W4+W6) +2ch(Master,Strobo)
- Dip2=On, Dip3=On: Mode4: 3ch(W1+W2, W3+W4, W5+W6) +2ch(Master,Strobo)

- Dip1=on enable add+2ch (Strobo)

- Dip4=Off

standard curve

-

- Dip4=On

ultrasoft curve

-

Functions  DipBCD:

9xx - 

AutoTest - gradual fade-over by the Mode

8xx - 

AutoTest - On W1+W4

7xx - 

AutoTest - On W2+W5

6xx - 

AutoTest - On W3+W6

5xx - 

AutoTest- On all

Order Code

Product name

Optic

(°)

LL36 080.1

LL STAGE 6-06D W (delivery with LL BEAM FRAME STAGE6)

Accessories

Order Code

Product name

LL37 200.1

LL BEAM FRAME STAGE 6-06 (1°)

LL37 220.1

LL FRAME STAGE  6-06 SQ6 MILKY

LL37 230.1

LL FRAME STAGE  6-06 R6 MILKY

LL37 232.1

LL FRAME STAGE  6-06 R6 CLEAR (120°)

LL36 300.1

LL BRACKET STAGE  6 SERIAL

LL36 320.1

LL BRACKET STAGE  6 PARALLEL DUAL (2pcs)

LL36 330.1

LL BRACKET STAGE  6 FIX

LL36 340.1

LL BRACKET STAGE  6 ADJUSTABLE

LL36 345.1

LL BRACKET STAGE  6 MATRIX 6x6

LL90 000

W-DMX MODUL 2,45GHz/5,8GHz DMX/RDM supply with W-DMX antenna

LL36 300

LL36 320

LL36 340

LL36 330

Mounting with LL BRACKET STAGE  6 MATRIX 6x6