If you have any question please, contact [email protected]
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
ventilating slots
sliding mounting brackets
Ch.
FLOOD WASH 600 RGBAW
Ch.
FLOOD WASH 1200 RGBAW
Mode1: Dip2=Off
1 Red 1,2,3
1 Red 1,2,3,4,5,6
2 Green 1,2,3
2 Green 1,2,3,4,5,6
3
Blue 1,2,3
3
Blue 1,2,3,4,5,6
4 Amber 1,2,3
4 Amber 1,2,3,4,5,6
5
White 1,2,3
5
White 1,2,3,4,5,6
6 Master (Dip1=On, Dip4=Off)
6 Master (Dip1=On,Dip4=Off)
7 Strobo (Dip1=On, Dip4=Off)
7 Strobo (Dip1=On,Dip4=Off)
Mode4: Dip2=On
1 Red 1
1 Red 1
18 Blue 4
2 Green 1
2 Green 1
19
Amber 4
3
Blue 1
3
Blue 1
20
White 4
4 Amber 1
4 Amber 1
21 Red 5
5
White 1
5
White 1
22 Green 5
6 Red 2
6 Red 2
23
Blue 5
7 Green 2
7 Green 2
24 Amber 5
8 Blue 2
8 Blue 2
25
White 5
9
Amber 2
9
Amber 2
26 Red 6
10
White 2
10
White 2
27 Green 6
11 Red 3
11 Red 3
28 Blue 6
12 Green 3
12 Green 3
29
Amber 6
13
Blue 3
13
Blue 3
30
White 6
14 Amber 3
14 Amber 3
31 Master (Dip1=On, Dip4=Off)
15
White 3
15
White 3
32 Strobo (Dip1=On, Dip4=Off)
16 Master (Dip1=On, Dip4=Off)
16 Red 4
17 Strobo (Dip1=On, Dip4=Off)
17 Green 4
Extention and control functions:
Dip4=Off, Dip1=Off =>DipBCD: use rotating switch for DMX start address
(RS1-100, RS2-010, RS3-001) from 001 to 511
Dip4=Off, Dip1=On: 2channel (Strobo)
Dip4=On, Dip1=Off: switch on AutoRun-table functions:
“100“=Prg.0-9, “10“=StepTime, “1“=FadeTime
Dip4=On, Dip1=On: switch all channels on 50% - test function
Dip2=Off: Mode 1 (5+2ch)
Dip2=Off: Mode 1 (5+2ch)
Dip2=On: Mode 4 (15+2ch)
Dip2=On: Mode 4 (30+2ch)
Dip3=Off: standard curve
Dip3=On: ultraSoft curve
Order
code
Product name
LL44 090
LL FLOOD WASH RGBAW 600
*
LL44 100
LL FLOOD WASH RGBAW 1200
*
* Optional 10°, 40°, EL (Eliptical 15°x90°), AS (Asymetrical) on request.
04 MAiNtENANcE
to tackle all Safety information- 01!
Damage caused by inadequate cleaning or maintenance is not coveredby warranty.
Regular cleaning is demand (dust, dirt, ...).
Maintenance policy:
Unplug mains before maintenance and at least 10 minutes cool off
Appliance do not illegal open or demount
Clean-up dust only from outer surface (for ex. scuttle, diffuser and lenses).
Use vacuum or dumpy duster (warm water)
Before reinstalling to check failure-free state – no wet parts!
-
-
-
-
-
-
-
-
03.5 DMX channels - subject to change
The latest version of DMX channels appendix are on the websites - www. leaderlight.eu
Adjustable bracket
Mechanical mounting of LL FLOOD WASH and Adjustable bracket
2.1 Fit the adjustable bracket on the fitting and fit with srews.
The installation of LL FLOOD WASH and Adjustable bracket is easy.
It is not necessary to
open the fixture before the mechanical mounting.
90°
AiMiNG POSSiBiLity
The fixture could be aim
to wish position with the
bracket.
2.2 The bracket fix to the solid surface with srews (minimal 4pcs).
1.1
minimal.
100mm
Ventilation space 180° free
Minimal mounting distance from surface
Ventilation space 90° free
iNStALLAtiON SPAcE
minimal.
200mm
minimal.
100mm
minimal.
100mm
WARNiNG!!!
Non-minimum distance and/or non-use
the original brackets is at your own risk!
!
!
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+