USER MANUAL
LL ARC SPOT 19 RGB
Leader Light s.r.o.
M.Gorkeho 33
SK-052 01 Spisska Nova Ves
Slovakia
www.leaderlight.eu
Content:
01 SAFETY INFORMATION
01.1 Risk of eyes damage
01.2 Protection from electric shock
01.3 Fire prevention
02 PROdUCT SPECIFICATION
02.1 Technical Specification
03 INSTALLATION
03.1 Unpacking
03.2 Physical installation
03.3 Electrical installation
03.3.1 Connecting to AC/DC power supply
03.3.2 Connecting to LL ARC DRIVER for intensity/colour control
04 MAINTENANCE
All dimensions are in millimeters
ENvIRONMENT
Do not throw away the appliance with the normal household waste at the end of its life,
but hand it in at an official collection point for recycling. By doing this, you help to preserve
the environment.
WARNING!!!
Carefully read before installing, powering or servicing.
Nothing to do if anything misunderstand! Installation can be done only
by a qualified professional in accordance with relevant local codes.
01 SAFETY INFORMATION
01.1 Risk of eyes damage
Do not look directly into LED lamps.
- Do not look into light beam from a distance of less than 40 cm (16 inches)!
-
01.2 Protection from electric shock
Shut down power before installation or maintenance.
Luminaries, Driver and recommended power supply must be installed by a qualified
professional in accordance with relevant local codes. Only acceptable source of power and
frequency that complies with local building and electrical codes to use.
Do not use or do not connect the products if the power cable, power plug or fixtures are any
way damaged, wet, or if they are overheating.
Do not modify, alter, or attempt to service the LeaderLight appliance. Doing so will void the
warranty.
Before removing or installing any cover or part of appliance disconnect from power.
-
-
-
-
-
01.3 Fire prevention
Follow all safety consideration.
Thermostatic switches or fuses never to bypass.
Device never shield. Around the axis of the fitting (180°) must be maintained space for
cooling. Minimum distance from the surrounding objects must be 100mm (4 in.) (figure 1.1).
LEDs never direct cover with filters or other materials.
Allowing max. ambient temperature is 40°C (104°F).
Luminaries never use without mounting brackets. The housing never install directly to the
surface.
-
-
-
-
-
-
02 PROdUCT SPECIFICATION
02.1 Technical Specification
03 INSTALLATION
03.1 Unpacking
Unpack carefully.
This is electronic equipment and should be handled carefully.
Damaged delivered package or if are any mechanical parts broken – it must be claim
immediately by the transport company. Photo pictures as evidence are valuable for
future claim.
-
-
-
03.2 Physical installation
Loading capacity of bearing area has to be at least 10 times the weight of all device
clusters (luminaries, clamps, cables, ...).
Hairbreadth from combustible materials is 0,5m.
-
-
©MMX - Leader Light – All right reserved
If you have any question please, contact [email protected]
COMPLIMENTS ON YOUR PURCHASE!
Edition: A - 2010
Lamp type:
7xR+6xG+6xB Z5
*
Lifetime:
Long 50 000 hrs 70% degradation
Optic:
Standard 25°, on request: 10°, 40°
Control data Input:
3 channels 24V dimming
Input power:
max. 25W
Power connection:
24V DC 5m cable with 6pin LINE connector
Net weight:
3kg
IP:
IP43 or IP65
Ambient temp. (Ta):
Maximum 40°C
Cooling:
Conventional
Materials and finish:
Powder-painted anodized aluminium RAL9006
(other colours on request)
Installation:
Surface mounting
*
Z5: R-Red, G-Green, B-Blue
WARNING!!!
!
!
Non-minimum distance and / or non-use the original brackets is at your own risk!
Operation only with dC 24v source!
By using a high voltage AC power supply - danger of electric shock!
Ventilation space 180° free
Minimal mounting distance from surface
1.1
INSTALLATION SPACE
Screw the fixture to the surface (M12 or 2xM10)
1.2
Surface installation
Unfix by hand the screw and aim the fixture to the wish position and fix.
180°
AIMING POSSIBILITY
The fixture could be aim to wish
position with bracket.
180°
minimal.
80mm
minimal.
80mm
Ventilation space 90° free
minimal.
100mm
minimal.
80mm
140
195
165
Following items are included:
- LL ARC SPOT 19 RGB with 5m cable and 6pin LINE connector
1 pc.
- User manual
1 pc.
Additional items needed:
- ARC DRIVER
-
DC
power supply 24V
-
Controller compatible with DMX
Surface mounting:
- Screws and washers 1xM12 or 2xM10
IP43:
LL33 700
IP65: