LEAD FLUID TECHNOLOGY CO.,LTD.
1) Switch the power off. Wire the DB15 connector as shown on
, and connect it to the DB15 port on the rear of the
pump.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
RS_W
Figure 22. Logic Level 1 Control with Internal 12V Power Source
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
12VDC
VCC_W
COM
RS_W
Figure 23. Logic Level 1 Control with External 12V Power Source
2) Turn on the power switch. Pump will display the main screen.
3) Press
MODE
key to change the mode to Logic Level 1 control mode
(shows lev1 on the screen).
4) Press
UP
or
DOWN
key to adjust the speed.
5) Press
DIRECTION
key to change the rotating direction.
6) When the switch is closed, the drive will start running; when the
switch is open, the drive will stop.
Note: Use this mode to work with a TIME CONTROLLER.
: