8.3 Connecting the sensor cable
The unit is compatible with two different sensor cable. The TS sensor cable
measures the battery temperature to optimally charge the battery. The CTS
sensor cable measures the battery temperature and voltage to optimally
charge the battery.
NOTE!
When connecting, pay attention to the instructions and notes in the
sensor cable installation instructions.
To connect the sensor cable, proceed as follows:
1. Insert the plug of the sensor cable into the connection for the temperature
sensor on the back of the unit.
ð
The sensor cable is connected.
8.4 Connecting the CBL control relay
A potential-free changeover contact is integrated in the
CPC chargers, which switches during charging. This op-
tion can be used, for example, to implement an electrical
start interlock with 230 V connection or charge monitor-
ing.
Switching function of the changeover contact
– Pin 1 and pin 3 are connected when the charger is
switched off.
– Pin 1 and pin 2 are connected when the charger is
switched on.
Technical Data (insula-
tion)
Capacity (max. values)
Output to housing
500 V 24 V (DC): 0.5 A
Output to ground
120 V 120 V (AC): 0.5 A
To connect the CBL control relay, proceed as follows:
1. Plug the RJ plug connector into the connector for the
CBL relay.
ð
The CBL control relay is connected.
18
LEAB Automotive GmbH
Thorshammer 6
24866 Busdorf
8 Installation
LEAB Automotive GmbH