Installation Instructions
Installation
Page 7 of 11
8
Installation
Fitting the Data Adapter
Connection
1 – single wire
2 – wake-up signal (D+)
3 – ground
4 – CAN high
5 – CAN low
It is not possible to operate the device without a wake-
up signal.
A CAN connection must also be established in order to
charge lithium batteries.
Connecting Batteries
To connect the batteries (starter battery and additional battery), perform the
following steps:
1.
Disconnect the batteries from the on-board power supply.
Warning: Disconnect the negative cable first.
2.
Secure the positive leads as close as possible to the batteries with
suitable fuses (50 A).
3.
Connect the outputs (2) and (4) of the device to the positive terminals of
the batteries.
4.
Connect the common ground (3) of the device to the negative terminals
of the battery.
5.
Connect the vehicle batteries to the on-board power supply.