![LEAB 1041003001 User Manual Download Page 9](http://html1.mh-extra.com/html/leab/1041003001/1041003001_user-manual_1864578009.webp)
ð
The device is ready for operation (‘LED Status’ flashes green).
5 Connect the starter battery to the on-board supply system.
ð
The BPC charge booster is connected to the starter battery.
Setting the Output Voltage
The BPC charge booster provides 3 different output voltages:
– 14.1 V for wet batteries
– 14.5 V for gel and AGM batteries
– 15 V for lithium batteries
An output voltage of 14.1 V is set at the factory.
To set the output voltage, perform the following steps:
6 Press the program button (approx. 6 seconds) until 'LED Failure' and 'LED
Status' illuminate green.
7 Press the program button for a further 3 seconds.
8 To choose between the output voltages, press the program button.
– LED Com: 14.1 V
– LED Failure: 14.5 V
– LED Status: 15 V
9 To store an output voltage, press the program button for 3 seconds until all
LEDs illuminate red.
ð
The output voltage is set. To check the set output voltage, see
7 Assembly
Notice
Device defect due to the effects of dust and moisture
The effects of dust and moisture can cause device defects
1. Choose a cool, dry and well-ventilated assembly site.
2. Protect the device from the effects of dust and moisture.
9
LEAB Automotive GmbH
Thorshammer 6
24866 Busdorf
LEAB Automotive GmbH