Lea LE75069-83 Original Instructions Manual Download Page 8

 

z

 

Do not touch the generator if you have wet hands.  

z

 

Do not operate the generator in wet conditions.  

z

 

Do not operate the generator near water.  

z

 

Never connect two generators together.  

z

 

Never connect the generator to any commercial power outlet.  

z

 

Make sure any extension cords used are in a safe condition and of sufficient capacity for 
the task.  

z

 

Ensure that the load on the generator falls within its capacity as specified in the table 
before plugging in any cords.  

6.3 Fire and burn hazards 

 

z

 

The exhaust system gets hot enough to ignite some materials:  

z

 

keep the generator at least 1 meter away from buildings and other equipment during 
operation.  

z

 

keep flammable materials away from the generator.  

z

 

The exhaust becomes very hot during operations and remains hot for a while after 
stopping the engine:  

-

 

let the engine cool before storing the generator indoors.  

-

 

do not touch the hot exhaust with your hands.  

z

 

Gasoline is extremely flammable and is explosive under certain conditions. Do not smoke 
or allow flames or sparks where the generator is refueled or where gasoline is stored.  

z

 

Fuel vapors are extremely flammable and may ignite after the engine has started. Make 
sure that any spilled fuel has been wiped up before starting the generator.  

7. USE 

 

7.1 Before starting the generator 

 

The generator ground terminal is connected to the frame of the generator, the metal non-
current-carrying parts of the generator, and the ground terminals of each receptacle. Before 
using the ground terminal, consult a qualified electrician, electrical inspector or local agency 
having jurisdiction for local codes or ordinances that apply to the intended use of the generator.  

7.2 Fill and check fuel level (Fig. 2) 

 

Use mixed petrol (1:50) only. You can use the fuel cap to measure the quantity of the 2-stroke oil.  

-

 

Remove any power cords  

-

 

Turn power switches off  

-

 

Do not overfill – do not fill above fuel filter top  

-

 

Always screw down fuel cap  

-

 

Clean up any spilled fuel  

-

 

Do not smoke while operating the generator  

Always use caution! 

 

7.3 Starting the generator (Fig. 1) 

 

1)

 

Disconnect electric apparatus  

2)

 

Turn on fuel tap (10).  

3)

 

Turn on engine switch (2).  

Summary of Contents for LE75069-83

Page 1: ...GENERATOR GENERATORE LE75069 83 Original instructions Istruzioni originali...

Page 2: ...Fig 1...

Page 3: ...Fig 2 Fig 3 Fig 4 0 7 0 8mm...

Page 4: ...el tap 4 Recoil starter 11 Spark plug 5 AC socket 12 Exhaust 6 AC protector 13 Ground terminal 7 Rubber feet 14 Air filter cover 3 TECHNICAL DATA Generator LE75069 83 Rated voltage 230 V Rated frequen...

Page 5: ...d operate the tool in rain Engines give off carbon monoxide an odorless colorless poison gas Breathing carbon monoxide can cause nausea fainting or death For outdoor use only Choke closed Choke open G...

Page 6: ...l Keep the cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of a lethal electric shock z When operating a power tool outdoors use an extension cable sui...

Page 7: ...s are potentially dangerous in the hands of untrained users z Maintenance Check for misalignment or jammed moving parts breakages or any other feature that might affect the operation of the power tool...

Page 8: ...e under certain conditions Do not smoke or allow flames or sparks where the generator is refueled or where gasoline is stored z Fuel vapors are extremely flammable and may ignite after the engine has...

Page 9: ...Clean the fuel filter Replace if necessary Clean the exhaust decarbonisation Replace if necessary 8 2 Service notes on maintenance 8 2 1 Spark plug inspection Fig 3 Disconnect the spark plug cap and r...

Page 10: ...Cleaning Clean the housing regularly with a soft cloth preferably every time it is used Keep the air vents free of dust and dirt Remove stubborn dirt with a soft rag moistened in soapy water Do not us...

Page 11: ...is not suitable incompetent usage e g not following the instructions given in the manual inexpert assembly lightning strike erroneus net voltage This list is not exhaustive z Acceptance of claims unde...

Page 12: ...ance withthe provisions of the following European directives 2006 42 EC Machinery 2004 108 EC ElectroMagnetic Compatibility 2000 14 EC 2005 88 EC Noiseoutdoor 97 68 CE 2010 26 EU And to the followings...

Page 13: ...AC 12 Scappamento 6 Protettore AC 13 Terminale di messa a terra 7 Gomma 14 Copertura del filtro dell arialist 3 DATI TECNICI Generatore LE75069 83 GG1000 Tensione nominale 230 V Frequenza nominale 50...

Page 14: ...ni e i gas di scarico sono molto caldi L accensione del motore provoca scintille Le scintille potrebbero incendiare i gas infiammabili nelle vicinanze Non utilizzare sotto la pioggia e non lasciare al...

Page 15: ...utilizzare adattatori insieme ad apparecchi collegati a terra Spine non modificate e prese di corrente adatte riducono il rischio di scosse elettriche z Evitare il contatto fisico con superfici colle...

Page 16: ...ere 5 4 Uso attento e scrupoloso degli elettroutensili z Non sovraccaricare l apparecchio Utilizzare l elettroutensile idoneo al lavoro da svolgere Con un elettroutensile adatto si potr lavorare megli...

Page 17: ...biano una capacit sufficiente per lo scopo Assicurarsi che il carico del generatore rientri nella sua capacit come specificato nella tavola prima di attaccare qualsiasi filo 6 3 Pericoli di incendio e...

Page 18: ...e del motore 2 4 Spostare la leva della bobina di arresto 3 sulla posizione chiuso per riavviare a motore caldo lasciare la leva della bobina di arresto sulla posizione aperto o semi aperto 5 Tirare l...

Page 19: ...copertura del filtro dell aria 14 Rimuovere l elemento filtrante e lavarlo bene in un solvente Versare una piccola quantit di olio nell elemento filtrante e spremere delicatamente l olio in eccesso R...

Page 20: ...otto antiruggine Posizionare il generatore su un piano e coprirlo con un panno asciutto e pulito 9 GARANZIA Questo prodotto garantito per un periodo di 24 mesi a decorrere dalla data dell acquisto da...

Page 21: ...arbonio ecc Conservare lo scontrino come prova della data d acquisto L apparecchio non smontato deve essere restituito al rivenditore in condizioni di pulizia accettabili nella custodia preformata ori...

Page 22: ...VI 2005 88 EC conforme alle seguenti direttive CE Compatibilit elettromagnetica 2004 108 CE Macchine 2006 42 CE Emissione acustica ambientale 2000 14 CE 97 68 CE 2010 26 EU E in ottemperanza alle segu...

Page 23: ...9 www dunsch com...

Reviews: