- Make sure to tighten all screws after control lever assembly.
Adjusting the ram travel (Fig.8 & 9)
Should your logs be much shorter, the machine working capacity can be increased by to
adjusting the ram stroke accordingly. The ram stoke adjustment is possible at all times.
1. Place a log on the working table and let the ram slide down until the wedge is about 2cm
from the log (Fig.8).
2. Disengage one of the control levers in order to prevent the ram from returning back to its
upper start position.
3. Switch off and unplug machine from its power supply.
4. Release the second control lever handle.
5.
(a) Release the knob (A in Fig.9) on the rear
(b) Pull up the control rod (B in Fig.9) as much as possible, until desired length is set.
(c) Once the rod is pulled sufficiently up to obtain the desired ram stroke, tight the knob
back to the original torque.
The ram travel is now shorter than the original full-stroke.
The ram travel adjustments to the original full-stroke length can be repeated at all times by
simply releasing the knob, pushing the rod back and tightening the knob again
Table height adjustment (Fig.10)
a) The log splitter table can be hanged-up at three different levels: 580/770/1060mm
- Upper position: for logs with max length of 580mm.
- Middle position: for logs with max length of 770mm.
- Lower position: for logs with max length of 1060mm.
b) Adjusting the table
Changing the table level can be easily performed without any additional tool or help, simply
proceed as follows:
1.
Remove the safety lock (a) on both sides of support brackets.
2.
Slightly lift table up and pull it out towards you.
3.
Slip and insert the table onto the desired level support bracket (according to the length of
the log),
4.
Let the table settle down making sure that the rear table hooks are well and firmly settle
on the bracket support. Lock in place.
5.3 Electrical requirements
With a 230V~ 50Hz motor, the log splitter should be connected to standard 230V
±
10%
(50Hz
±
1Hz).
The electrical supply must be fitted with protection devices of under-voltage, over-voltage,
and over-current as well as a residual current device (RCD), which maximum residual current
rated at 0.03A.
Electrical connection rubber cables must comply with EN60245 which are always marked with
H07RN, and with cross section greater than 1.5mm
2
.
Wiring and Plumbing diagrams
Summary of Contents for LE581504H
Page 2: ...Fig 1 Fig 2 Fig 3 Fig 4a Fig 4b Fig 4c Fig 4d Fig 4e...
Page 3: ...Fig 5 Fig 6 Fig 7 Fig 8 Fig 9...
Page 4: ...Fig 10 Fig 11 Fig 12 Fig 13...
Page 5: ...Fig 14 Fig 15 Fig 16 Fig 17 Fig 18 Fig 19...
Page 6: ...Fig 20 Fig 21 Fig 22 Fig 23 Fig 24 Fig 25A Fig 25B...
Page 7: ...12 19 Fig 26 Fig 27 Fig 28A Fig 28B Fig 29 Fig 30...
Page 74: ...9 www dunsch com...