Using the Remote

Using the Remote

Using the Remote

Using the Remote

Using the Remote

1.  Fog time is set using the DURATIONcontrol (1

à

30 seconds).

2.  Time between fog outputs is set using the INTERVAL control (0

à

20 minutes).

3.  Fog output level is set with VARIFLOW CONTROL.

NOTE:  To re-program the settings on the Variflow remote,, insure that the smoke on-off switch is truned off a

minimum of four seconds to clear the remote's existing "memory".

EXAMPLES

EXAMPLES

EXAMPLES

EXAMPLES

EXAMPLES

1.  Medium fog 30 seconds duration every 10 minutes

- set VARIFLOW to 50% (adjust as required)
- set DURATION to 30
- set INTERVAL to 10

2.  Maximum fog maximum duration

- set VARIFLOW to PRIME
- set DURATION to 30
- set INTERVAL to 0 (this shuts off timer)

*Note:  Setting INTERVAL to zero and DURATIONto 30 will allow over 30 seconds of fog time, limited only by

thermal protection circuitry.

3.  Continous fog output - low level

- set VARIFLOW to approximately 60% level or less (adjust to requirements)
- set DURATION to 30 (maximum continous)
- set INTERVAL to 0 (this switches off the timer)

*Note:  Safe and reliable operating parameters, integral in the Show Mist Pro. design, delicate that the heat

exchanger maintain a closely regulated operation temperature.  It's capability to do this is affected by
two factors: (1)  AC available to it (ie. 115 volt/15amps) (2)  The volume of coolant (ie. fog fluid) being
pumped through it.  Since more AC is not available (ie.200 volt), the block must see less coolant (less
smoke output) to run continuously.  Gradually increasing output (pumping more "coolant" through the
block) will eventually cool the block sufficiently that thermal sensors will trigger the Show Mist Pro's
circuitry, and shut off the fluid pump to allow time for the block to reheat.