Venting Methods:
Re-Circulating Function Methods:
This range hood is factory set for venting through the roof or wall.
• Vent work can terminate either through the roof or wall. To vent through a wall, a 90°
elbow is needed.
IMPORTANT:
• NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces,
ceiling, attics or garages. All exhaust must be ducted to the outside.
• Use metal/aluminum duct work only.
• Fasten all connections with sheet metal screws and tape all joints with certified Silver
Tape or Duct Tape.
• Use caulking to seal exterior wall or roof opening around the cap. ( Not included)
Re-circulating function is intended for applications where an exhaust duct work is not possible to be
installed. When converted, the hood functions as a purifying hood rather than an exhaust hood. Fumes
and exhaust from cooking is drawn and filtered by a set of charcoal filters. The air is then purified and
re-circulated back within the home.
• We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new
duct work, if possible. Only when the exhaust option is not possible should you recourse to converting
the hood into a purifying unit.
• When converted to be a “purifying” unit, a charcoal filter is required in addition to its standard aluminum
filter set. Available online only!!!. The standard aluminum filters are intended to capture residue from
cooking, the optional charcoal filters help to purify fumes exhausted from cooking.
Option 1: Vertical roof
venting
Option 2: Horizontal wall venting
Roof cap
Side wall cap
7