DigitalBooster DB-4 – Manual
-
15
-
The
programming
for the
on-/off switch function
is now
completed
but can
repeated at any time.
3.
Depress
now again the
key S1
to come into the
programming mode
for the
address section
of the
WatchDog-Function
. The
red LED flashes
.
4.
Switch
now
one turnout
from the
group of four
which has been selected for the
address section
of the
WatchDog-Function
via the
keyboard
of the
digital
command station
or the
remote control
. For
programming
the
address
section
you can
send
as well a
turnout signal
via your
model railway software
.
Remarks:
It is possible to
select
for the
WatchDog-Function
the
same address
section
as you used already for programming the
On-/Off switch function
. But
you can select as well an
own four-fold address block
for the
WatchDog-
Function
.
If the
DigitalBooster DB-4
understands
the
address
the
DB-4
will
confirm
the
assignment by
flashing the red LED a little faster
.
Following
the
red LED
will
flash slower
again. The
programming
for the
On-/Off switch function
is now
completed
but can be repeated at any time.
Leave
now the
programming mode
of the
DB-4
by depressing again the
programming
key S1
. The
programmed addresses
are now
permanently stored
but can be
changed
at any time by
repeating
the
programming process
. Now the
green LED
will
glow
and the
track section
which is
connected
to the
DB-4
will get
supply
of
digital
voltage
.
8. WatchDog: Communication with the Model Railway Software:
If your
model railway software
supports
the
WatchDog-Function
of the
DB-4
respectively our
WatchDog-Decoder WD-DEC
please register in your
model railway
software
your selected address for the
WatchDog-Function
. It is always the
first
address
(
basic address
)
of the
selected
group of four
.
Function:
After switching-on
the
DigitalBooster DB-4
is the
WatchDog-Function
not activated
to enable the
operation
of the
model railway layout
eventually
without PC-control via
the
digital command station
.
The
model railway software
can
activate
the
WatchDog-Function
with the command
basic address
“
straight
” and has to
confirm
always
within 5 seconds
with a
new
command basic address
“
straight
”. If there is
no confirmation within
5 seconds
the
model railway software has lost control
over the
model railway layout
. The
Digital
Booster DB-4
will switch the
track voltage free
and all trains will stop immediately
.
The
red LED
of the
DB-4 will flash
and
indicates
therefore the