background image

Cetra F & PC 100 LED  User’s Manual – 1.0 

 

 

Luci della Ribalta srl, Via Berna 14, 46042 Castel Goffredo (MN) Italy 

Tel. +39 0376 771 777 – fax +39 0376 772 140 – emai

[email protected]

 – web www.ldr.it 

1.   BOX CONTENTS 

Upon opening the packaging, please make sure it contains the following: 

a.

 

lighting unit in the chosen model 

b.

 

metal colour frame 150x150mm, fitted 

c.

 

Neutrik PowerCon blue connector 

d.

 

160cm mains power cable 

 

Should one or more items miss, we kindly ask you to contact your dealer immediately. 

 

 

2.  WEIGHT AND DIMENSIONS 

 

 

       

 

 

 

 

 

Cetra f100 LED 

 

 

 

 

 

 

Cetra pc100 LED 

net weight: 5,9 kg   

 

 

 

 

 

net weight: 6,1 kg 

gross weight: 7,3 kg 

 

 

 

 

 

gross weight: 7,1 kg 

packing dimensions: 48x32x32h cm  

 

 

 

packing dimensions: 48x32x32h cm 

 

 

2.   OVERVIEW OF LED SPOTLIGHTS 

In comparison with conventional tungsten-halogen spotlights, Cetra has an LED solid-state electronic light source, which is 

more energy efficient and longer lasting than a tungsten-halogen lamp. The implications of using an LED source are as 

follows: 
A 89W LED is ‘built-in’ to the spotlight, and when the time comes to replace it, this will require servicing via your local 
dealer. The LED is not a plug-in replacement component and is not user-serviceable.  

The colour temperature of the LED is fixed at either ‘warm’ 3200K theatre-standard, or ‘cool’ 5600K, which is becoming 
more common in TV studio applications and in theatres using colour filters. 
Although regular colour filters may be used with an LED source, the non-continuous  spectrum of the LED produces a 
different effect with many standard colours. Lee Filters, Rosco and other manufacturers supply colour filters specifically for 
use with LED spotlights. These LED filters are generally matched to 5600K (cool) white sources. Please check you are using 
the correct source/filter combination. 

The spotlight requires a constant mains power supply (not a dimmed supply) and a DMX signal. The DMX signal is used to 
control intensity and performance features of the spotlight. Refer to the operational section of this manual for details. 

 

3.   MECHANICAL OPERATION 
The mounting stirrup 

is designed to allow the spotlight to be suspended from above using a C-clamp or similar, or 

supported on a stand or bracket from below. 

Note: 

the spotlight’s location must provide suitable ventilation for the LED 

module. 

Focus controls 

is located on the rear end of the product.  Turn the knob  clockwise  to narrow the beam (SPOT) . Turn the 

knob anticlockwise to widen the beam (FLOOD)  . The beam distribution (peak/flat) is fixed. 

Beam-shaping

  a 4 leaf barndoors can be fitted on the front of the Cetra to control and shape the beam  

 

 

Summary of Contents for Cetra F100 C

Page 1: ... PC100 W LED 3200K Cetra PC100 C LED 5600K istruzioni per l uso operating instructions Bedienungsanleitung instrucciones de manejo mode d emploi gebruiksaanwijzing Luci della Ribalta srl Via Berna 14 46042 Castel Goffredo mn Italy tel 39 0376 771 777 fax 39 0376 772 140 email info ldr it ...

Page 2: ...TION Local control panel and operation 4 4 1 DMX or manual 4 4 2 DMX address 4 4 3 Dimmer resolution 4 4 4 DMX frequency control 5 4 5 Lost DMX signal 5 4 6 Strobe 5 4 7 Strobe speed 5 4 8 Dimming curve 6 4 9 Cut off dimming response 6 4 10 Dimming behaviour 6 4 11 LED frequency adjustment 6 4 12 LCD retro illumination 7 4 13 Software version and LED temperature 7 4 14 PRO BASIC 7 4 15 Reset 7 MAI...

Page 3: ...operating maintenance and safety procedures in this manual or those generally applicable to lighting equipment The limitation extends to damages for personal injury property damage loss of operations loss of profits loss of product or loss of time whether incurred in by the customer the customer s employees or a third party Apart from the instructions given on this manual all relevant safety and h...

Page 4: ...emperature of the LED is fixed at either warm 3200K theatre standard or cool 5600K which is becoming more common in TV studio applications and in theatres using colour filters Although regular colour filters may be used with an LED source the non continuous spectrum of the LED produces a different effect with many standard colours Lee Filters Rosco and other manufacturers supply colour filters spe...

Page 5: ...s 4 1 DMX OR MANUAL Mode Select the LED control mode between DMX factory setting and manual To change the control mode press once the rotary selector until an arrow appears on the menu Turn the selector to the right or the left to select the desired mode of operation and press to confirm your selection Tap the rotary selector and the LCD screen will display the mode status and the current value 4 ...

Page 6: ...en it is remotely controlled through DMX required DMXCfg function enabled Factory setting OPEN 3 8 16b 8 BITS PRESS THE ROTARY SELECTOR TO ACTIVATE 3 8 16b 8 BITS 3 8 16b 16 BITS TURN TO SELECT MANUAL OR DMX AND PRESS TO CONFIRM 4 DMXCfg OFF PRESS THE ROTARY SELECTOR TO ACTIVATE 4 DMXCfg OFF 4 DMXCfg ON TURN TO SELECT MANUAL OR DMX AND PRESS TO CONFIRM PRESS TO ACTIVATE THE MENU AN ARROW SHOULD AP...

Page 7: ...as The frequency can be adjusted from a selection of 13th different values between 2KHz to 460Hz When DMXCfg function is enabled the frequency is controlled through the dedicated DMX channel and this menu becomes inactive Factory setting 2kHz PRESS TO ACTIVATE THE MENU AN ARROW SHOULD APPEAR 8 Curves LED_HALO REPRODUCE HALOGEN LAMP BEHAVIOUR 8 Curves LED_HALO 8 Curves LINEAR LINEAR DIMMING CONTROL...

Page 8: ...MENT The fuse holder is fitted on the rear of the unit Type 6 3A 5x20mm 250 VAC DC fast blow fuse CAUTION Replace the fuse only when power is disconnected 6 CLEANING AND MAINTENANCE To ensure maximum performance of the product a regular maintenance service should be carried out Please make sure the product is cold and disconnected from power supply when doing this clean all reflective parts such a...

Page 9: ... controlled through DMX DMXCfg function enable OPEN ON SPEED xx select value from 01 slowest to 10 fastest CLOSED OFF OPEN 8 Curves select the dimming curve LED HAL SQUARE LINEAR LED HAL 9 CutOff replicate the halogen lamp dimming behaviour at cut off FAST NOT ACTIVE SLOW ACTIVE SLOW 10 Smooth dimmere response OFF Immediate response SLOW 300ms FAST 150ms Smooth 11 Freq set the LED frequency This m...

Page 10: ...80 Speed 81 100 Speed 101 120 Speed 121 140 Speed 141 160 Speed 161 180 Speed 181 200 Speed 201 220 Speed fast 221 240 Closed and reserved 241 255 Closed 4 Frequency 00 20 3 kHz available only if 21 40 2 4 kHz DMX Cfg ON 41 60 2 0 kHz OFF by deafault 61 80 1 7 kHz Note 81 100 1 5 kHz for technical reasons all frequencies may not be available on all products 141 160 1 1 kHz 161 180 939 Hz 181 200 7...

Page 11: ...ben declaran bajo su responsabilidad que los productos aquì listados I sono conformi alle seguenti norme ed ai requisiti delle seguenti direttive CEE GB conform to the following standards and to the requirements of following EEC directives D den nachfolgend aufgeführten Normen und EEC Vorschriften entsprechen F sont conformes aux normes et prescriptions CEE ci aprés E cumplen de hecho con las sigu...

Page 12: ...so Faulty product Defekte s Produkt Produit défectueux Producto defectuoso Descrizione del problema Problem found Beschreibung des Defekts Description du défaut Descripciòn del problema ________________________________________________________________________________________________________ ________________________________________________________________________________________________________ ____...

Page 13: ...Luci della Ribalta srl Via Berna 14 46042 Castel Goffredo mn Italy tel 39 0376 771 777 fax 39 0376 772 140 email info ldr it ...

Reviews: