background image

Astro

 

LED

 

followspot

 

User’s

 

Manual

 

 

1.0

 

 

 

Luci

 

della

 

Ribalta

 

srl,

 

Via

 

Berna

 

14,

 

46042

 

Castel

 

Goffredo

 

(MN)

 

Italy

 

Tel.

 

+39

 

0376

 

771

 

777

 

 

fax

 

+39

 

0376

 

772

 

140

 

 

email

 

[email protected]

 

 

web

 

www.ldr.it

 

8

12.4

 

To

 

use

 

a

 

preloaded

 

lighting

 

effect

 

The

 

spotlight

 

has

 

8

 

pre

programmed

 

effects

 

to

 

provide

 

stand

alone

 

display

 

illumination

 

or

 

for

 

demonstrations

 

without

 

a

 

control

 

desk:

 

0

 

=

 

effects

 

off

 

1

 

=

 

Flashing

 

10

 

times

 

2

 

=

 

Flashing

 

20

 

times

 

3

 

=

 

Flashing

 

10

 

times

  

4

 

=

 

Flashing

 

20

 

times

 

5

 

=

 

Fade

 

in

 

and

 

fade

 

out

 

10

 

times

 

6

 

=

 

Fade

 

in

 

and

 

fade

 

out

 

5

 

times

 

7

 

=

 

Fade

 

in

 

and

 

fade

 

out

 

3

 

times

 

8

 

=

 

Fade

 

in

 

and

 

fade

 

out

 

2

 

times

 

 

1.

 

From

 

the

 

DMX

 

address

 

display,

 

press

 

the

 

down

 

arrow

 

to

 

show

 

9n00.

 

Press

 

ENTER

 

and

 

the

 

display

 

changes

 

to

 

9.n.0.0.

 

(0

 

=

 

effects

 

off).

 

2.

 

Use

 

the

 

up/down

 

buttons

 

to

 

change

 

to

 

9.n.0.x

  

(change

 

0

 

to

 

an

 

effects

 

number

 

1

8).

  

3.

 

Press

 

ENTER

 

and

 

the

 

display

 

will

 

show

 

the

 

selected

 

mode.

  

4.

 

This

 

feature

 

can

 

be

 

also

 

controlled

 

from

 

the

 

desk

 

(details

 

below).

 

12.5

 

To

 

change

 

dimmer

 

resolution

 

(coarse

 

or

 

fine)

  

1.

 

From

 

the

 

DMX

 

address

 

display,

 

press

 

the

 

down

 

arrow

 

to

 

show

 

CL00.

 

Press

 

ENTER

 

and

 

the

 

display

 

changes

 

to

 

C.L.0.0.

 

2.

 

Use

 

the

 

up/down

 

buttons

 

to

 

select

 

0

 

for

 

256

 

steps

 

(coarse

 

fade)

 

or

 

1

 

for

 

512

 

steps

 

(fine

 

fade)

 

3.

 

Press

 

ENTER

 

and

 

the

 

display

 

will

 

show

 

the

 

selected

 

mode.

 

4.

 

This

 

feature

 

can

 

be

 

also

 

controlled

 

from

 

the

 

desk

 

(details

 

below).

 

12.6

 

To

 

reset

 

the

 

unit

 

The

 

reset

 

process

 

performs

 

a

 

power

 

cycle

 

(off

on).

 

The

 

preference

 

settings

 

and

 

DMX

 

address(es)

 

remain

 

unaltered.

 

1.

 

From

 

the

 

DMX

 

address

 

display,

 

press

 

the

 

down

 

arrow

 

to

 

show

 

rL00.

 

Press

 

ENTER

 

and

 

the

 

display

 

changes

 

to

 

r.L.0.0.

 

2.

 

Use

 

the

 

up/down

 

buttons

 

to

 

select

 

1

 

for

 

a

 

reset

 

(

0

 

=

 

normal

 

control).

 

3.

 

Press

 

ENTER

 

to

 

perform

 

a

 

reset.

 

4.

 

This

 

feature

 

can

 

be

 

also

 

controlled

 

from

 

the

 

desk

 

(details

 

below).

 

12.7

 

Control

 

panel

 

display

 

sleep

 

mode

 

1.

 

From

 

the

 

DMX

 

address

 

display,

 

press

 

the

 

down

 

arrow

 

to

 

show

 

LL04.

 

Press

 

ENTER

 

and

 

the

 

display

 

changes

 

to

 

L.L.0.4.

 

2.

 

Use

 

the

 

up/down

 

buttons

 

to

 

select

 

the

 

time

 

to

 

elapse

 

before

 

the

 

display

 

is

 

switched

 

off:

 

1

 

=

 

Display

 

off

 

after

 

30

 

seconds

 

2

 

=

 

Display

 

off

 

after

 

45

 

seconds

 

3

 

=

 

Display

 

off

 

after

 

60

 

seconds

 

4

 

=

 

Continuously

 

on

 

(default)

 

3.

 

Press

 

ENTER

 

and

 

the

 

display

 

will

 

show

 

the

 

selected

 

mode.

 

4.

 

This

 

feature

 

can

 

be

 

also

 

controlled

 

from

 

the

 

desk

 

(details

 

below).

 

 

 

Summary of Contents for Astro 200 C

Page 1: ...ED 5600K istruzioni per l uso operating instructions Bedienungsanleitung instrucciones de manejo mode d emploi gebruiksaanwijzing Luci della Ribalta srl Via Berna 14 46042 Castel Goffredo mn Italy tel 39 0376 771 777 fax 39 0376 772 140 email info ldr it ...

Page 2: ...erature priority 7 12 4 To use a preloaded lighting effect 8 12 5 To change dimmer resolution 8 12 6 To reset the spotlight 8 12 7 Control panel display sleep mode 8 12 8 To set the maximum fan speed 9 12 9 To check LED temperature 9 12 10 To check dimming value 9 12 11 To check function status 9 13 Remote control features 9 13 1 To change from DMX to local control from a remote desk 9 13 2 To ove...

Page 3: ...dental special or consequential damages resulting from the customer s failure to follow the installation operating maintenance and safety procedures in this manual or those generally applicable to lighting equipment The limitation extends to damages for personal injury property damage loss of operations loss of profits loss of product or loss of time whether incurred in by the customer the custome...

Page 4: ... implications of using an LED source are as follows A 200W LED is built in to the spotlight and when the time comes to replace it this will require servicing via your local dealer The LED is not a plug in replacement component and is not user serviceable The colour temperature of the LED is fixed at either warm 3200K theatre standard or cool 5600K which is becoming more common in TV studio applica...

Page 5: ...k on weight 5 MOUNTING THE COLOUR CHANGER accessory part nr 20105106 Remove the colour frame from the followspot At the front of the followspot remove the 2 cross head self tapping screws from one of the two front colour runners Re position the two screws in their original holes and tighten them Repeat with the second colour runner Take the supplied M4 screws and position each one of them only hal...

Page 6: ...le items and relevant part number is R80852039 8 ADJUSTING THE YOKE This followspot is provided with a yoke balancing adjustment The balancing point is factory set for a standard usage of the product however should you need to adjust the balancing please proceed as follows a the followspot must be trIpod mounted b using a Phillips screw driver slacken the 2 M5 screws on each side of the yoke c gen...

Page 7: ...dicator will light When the power switch is turned on the followspot will perform a self check and if a DMX signal is present the display will show the dimmer DMX address initial factory default setting is A001 One DMX address is used for intensity and up to 7 additional addresses may be used for other remotely controlled functions Note The intensity DMX address must be set as a unique number and ...

Page 8: ...he display will show the new address 12 2 To change from DMX to local control 1 From the DMX address display press the down arrow to show dL01 Press ENTER and the display changes to d L 0 1 2 Use the up down buttons to select 2 for manual control or 1 for DMX control 3 Press ENTER and the display will show the selected mode 4 This feature can be also overridden from the control desk details below ...

Page 9: ...ss the down arrow to show CL00 Press ENTER and the display changes to C L 0 0 2 Use the up down buttons to select 0 for 256 steps coarse fade or 1 for 512 steps fine fade 3 Press ENTER and the display will show the selected mode 4 This feature can be also controlled from the desk details below 12 6 To reset the unit The reset process performs a power cycle off on The preference settings and DMX ad...

Page 10: ... or 1 32 F 212 F 3 Press ENTER and the display will show the selected temperature range 4 NOTE there are two possible error messages tErL under the lowest limit tErH over temperature 12 10 To check dimming value From the DMX address display press the down arrow to show AH DMX level 00 FF Ad local control level 00 FF 12 11 To check function status From the DMX address display press the down arrow t...

Page 11: ...s off DMX values 16 31 Flashing 10 times DMX values 32 47 Flashing 20 times DMX values 48 63 Flashing 10 times DMX values 64 79 Flashing 20 times DMX values 80 95 Fade in and fade out 10 times DMX values 96 111 Fade in and fade out 5 times DMX values 112 127 Fade in and fade out 3 times DMX values 128 255 Fade in and fade out 2 times 13 4 To change dimmer resolution course or fine from a remote de...

Page 12: ...l mode address 1 512 Note this must be a unique DMX address and set to independent on the control desk 3 Press ENTER and the display will show the selected mode 4 Use the selected DMX address on the remote desk follows DMX values 0 31 100 maximum DMX values 32 63 90 of max DMX values 64 95 80 of max DMX values 96 127 70 of max DMX values 128 255 60 of max 14 CONTROL MENU SUMMARY Menu in order of d...

Page 13: ...ss r e g r128 DMX 128 for remote reset 000 254 normal control 255 reset 001 LED sleep display LL0 LL01 Display off after 30 seconds LL02 Display off after 45 seconds LL03 Display off after 60 seconds LL04 Continuously on default 4 LED sleep display control address L e g L129 DMX 129 for LED sleep display 000 063 Display off after 30 seconds 064 127 Display off after 45 seconds 128 191 Display off ...

Page 14: ...ps and replace any visibly damaged component clean air ducts and fans to ensure adequate ventilation for the LED engine and power supply check internal and external wiring and replace any cable which has obvious mechanical damage or has been affected by heat 17 SPARE PARTS All components are available as spare parts We strongly recommend you always use original LDR components as spare parts Please...

Page 15: ...sponsabilidad que los productos aquì listados I sono conformi alle seguenti norme ed ai requisiti delle seguenti direttive CEE GB conform to the following standards and to the requirements of following EEC directives D den nachfolgend aufgeführten Normen und EEC Vorschriften entsprechen F sont conformes aux normes et prescriptions CEE ci aprés E cumplen de hecho con las siguientes normas y directi...

Page 16: ...t Produit défectueux Producto defectuoso Descrizione del problema Problem found Beschreibung des Defekts Description du défaut Descripciòn del problema ________________________________________________________________________________________________________ ________________________________________________________________________________________________________ ______________________________________...

Page 17: ...ble for delivering the appliance to an appropriate collection facility at the end of its useful lifespan Appropriate separate collection to permit recycling treatment and environmentally compatible disposal helps prevent negative impact on the environment and human health and promotes recycling of the materials making up the product For more information on available collection facilities contact y...

Page 18: ...Luci della Ribalta srl Via Berna 14 46042 Castel Goffredo mn Italy tel 39 0376 771 777 fax 39 0376 772 140 email info ldr it ...

Reviews: