background image

Astro  250 HP 3200K and 5600K, DMX 512+ RDM LED followspot -  User’s Manual – 1.0 

 

 

Luci della Ribalta srl, Via Berna 14, 46042 Castel Goffredo (MN) Italy 

Tel. +39 0376 771 777 – fax +39 0376 772 140 – emai

[email protected]

 – web www.ldr.it 

11.5    STROBE (Strobe): 

This function enables to activate the strobe function. Factory setting is DISABLE.  

 

 

 

 

 

11.6   STROBE SPEED (SetStr) : 

It allows to set the strobe speed. This menu is not active when the strobe function is disabled or 

when it is remotely controlled through DMX. Factory setting is OPEN. 

 

 

 

 

 

 

 

 

 

 

 

11.7   DIMMING CURVE (Curves)  

This function allows to select a response curve for the Astro LED. A choice of two curves is available: 

Square and Linear.  Factory setting is SQUARE. 

 

 

 

 

 

 

 

11.8   CUT OFF DIMMING RESPONSE (CutOff) : 

This function allows to select the LED behaviour simulating a tungsten or halogen lamp during  the 

dimming cut off.  

Factory setting is SLOW. 

 

 

 

 

 

 

5

  Strobe 

DISABLE 

     

5

  Strobe 

DISABLE 

     

5

  Strobe 

ENABLE   

 

TURN  TO ENABLE OR 

DISABLE STROBE AND 

PRESS TO CONFIRM 

PRESS TO ACTIVATE 

THE MENU   

AN ARROW SHOULD 

APPEAR  

PRESS TO ACTIVATE 

THE MENU   

AN ARROW SHOULD 

APPEAR  

6 SetStr 

OPEN 

PRESS TO ACTIVATE 

THE MENU  

AN ARROW SHOULD 

APPEAR  

7 Curves 

SQUARE 

PRESS TO ACTIVATE 

THE MENU   

AN ARROW SHOULD 

APPEAR  

8 CutOff 

SLOW 

WITH STROBE ENABLE 

THE LIGHT IS SET TO ON 

6 SetStr 

OPEN       

     

6 SetStr 

SPEED #   

     

 

CHOOSE THE STROBE 

SPEED VALUE FROM 

1(SLOW) TO 10 (FAST)  

6 SetStr 

CLOSED  

     

 

WITH STROBE ENABLE 

THE LIGHT IS SET TO 

OFF  

SQUARE TO INCREASE 

VOLTAGE RESPONSE AT 

LOWER VALUE 

7 Curves 

SQUARE  

    

 

7 Curves 

LINEAR   

    

 

LINEAR DIMMING 

CONTROL 

SOFT LED DIMMING AT 

SHUT DOWN  

8 CutOff 

SLOW       

     

8 CutOff 

FAST        

 

 DIRECT DIMMING

 

RESPONSE AT SHUT 

DOWN 

Summary of Contents for 01207170

Page 1: ... 3200K Astro 250 plus HP 5600K 100 260V DMX512 RDM istruzioni per l uso operating instructions Bedienungsanleitung instrucciones de manejo mode d emploi gebruiksaanwijzing Luci della Ribalta srl Via Berna 14 46042 Castel Goffredo mn Italy tel 39 0376 771 777 fax 39 0376 772 140 email info ldr it ...

Page 2: ...ost DMX Signal page 6 11 5 Strobe page 7 11 6 Strobe Speed page 7 11 7 Dimming curve page 7 11 8 Cut off dimming response page 7 11 9 Dimming behaviour page 8 11 10 Fan Setting page 8 11 11 LCD Screen Illumination page 8 11 12 Temperature Control page 9 11 13 Software Version page 9 11 14 Manual Dimmer Type page 9 11 15 Pro or Basic Control page 9 11 16 Factory Settings page 9 11 17 ID for REMOTO ...

Page 3: ...ect indirect incidental special or consequential damages resulting from the customer s failure to follow the installation operating maintenance and safety procedures in this manual or those generally applicable to lighting equipment The limitation extends to damages for personal injury property damage loss of operations loss of profits loss of product or loss of time whether incurred in by the cus...

Page 4: ... the tripod you are going to use can withstand the product load as indicated on the product s label Make sure the tripod you are going to use features a top aperture over 28mm dia Remove the M12 nut and the washer from the spigot Insert the spigot in the central hole of the yoke of the followspot from beneath the yoke Add the plain screw and the M12 self locking nut and tighten the nut with a suit...

Page 5: ... THE IRIS AND THE FOLLOWSPOT TO SUFFER MAJOR HEAT DAMAGES AND WILL INVALIDATE THE PRODUCT WARRANTY 6 SHUTTER BLADES accessory part nr R80208019 x 4 Shutter blades are not supplied with the unit but are available as separate accessory They are sold as single items and relevant part number is R80208019 4 are required 7 ADJUSTING THE YOKE This followspot is provided with a yoke balancing adjustment T...

Page 6: ... to check the unit works correctly 9 VOLTAGE Before operating this unit please refer to the product label mounted at the back of the luminaire to check you are operating with the correct voltage The Astro 250 LED can be operated between 100V and 260 VAC 10 LOCAL CONTROL PANEL AND OPERATION OPERATION LCD display for DMX address system setup and status details POWER power LED status indicator red co...

Page 7: ...tting is 001 11 3 DIMMER RESOLUTION 8 16b The dimming resolution can be controlled at 8 bits from one DMX channel or 16 bits with 2 DMX channels Factory setting is 8 Bit 11 4 LOST DMX SIGNAL DMXMem In case of signal failure this function allows to store in memory the last DMX value Factory setting is ON Three options are available M Manual XX XXX M DMX XX 1 Mode DMX 1 Mode MANUAL TAP THE ROTARY SE...

Page 8: ...DIMMING RESPONSE CutOff This function allows to select the LED behaviour simulating a tungsten or halogen lamp during the dimming cut off Factory setting is SLOW 5 Strobe DISABLE 5 Strobe DISABLE 5 Strobe ENABLE TURN TO ENABLE OR DISABLE STROBE AND PRESS TO CONFIRM PRESS TO ACTIVATE THE MENU AN ARROW SHOULD APPEAR PRESS TO ACTIVATE THE MENU AN ARROW SHOULD APPEAR 6 SetStr OPEN PRESS TO ACTIVATE TH...

Page 9: ...m speed In all cases if the LED temperature exceeds the maximum admitted value the LED is protected by a derating security system Factory setting is AUTO 11 11 LCD SCREEN ILLUMINATION BackL This function allows to turn off the LCD backlight the LED POWER and LED DMX after 1 30 from last setting Factory setting is AutoOFF PRESS TO ACTIVATE THE MENU AN ARROW SHOULD APPEAR 9 Smooth NORMAL 11 BackL Au...

Page 10: ...the rotary switch at power on 11 15 PRO or BASIC CONTROL ProBasic The PRO BASIC control is a special function which allows to limit the access to the control menu Select ProBasic with the rotary switch and press to access the menu Select PRO to enable access to all the functions BASIC to limit access to functions 5 1 DMX or MANUAL MODE 5 2 DMX ADDRESS 5 12 Temperature Control and 5 13 Software ver...

Page 11: ...and rear zoom lenses in relation to each other The front lens defines the beam spread the rear lens defines the focus degree of softness or hardness of the beam edge or shutters 13 CLEANING AND MAINTENANCE To ensure maximum performance of the product a regular maintenance service should be carried out Please make sure the product is cold and disconnected from power supply when doing this General m...

Page 12: ...he date you purchased this product In case of complaints we strongly recommend you use the complaint form at the end of this manual or contact the local dealer who supplied the product to you In any case please report the serial number of the product 16 AVAILABLE ACCESSORIES A20100106 185x185mm colour frame A20109106 Kit 185x185mm colour frame front runners A20105106 5 colour colour changer magazi...

Page 13: ...lue OFF 80 fade to 80 after 1 5 Sec OFF 0 ON 5 Strobe Activates the Strobe function ENABLE DISABLE DISABLE 6 SetStr Selects the Strobe speed This menu is not active when the Strobe function is disabled or when is remotely controlled through DMX OPEN ON SPEED select value from 01 slowest to 10 fastest CLOSED OFF OPEN 7 Curves Selects the dimming curve SQUARE LINEAR SQUARE 8 CutOff Replicates the ha...

Page 14: ...minimum level of the output From 000 to 9999 E Exit Exits from hidden menus 19 DMX CHARTS 19 1 DMX chart 1 16 bit dimmer and strobe disabled This DMX chart refers to the followspot set at default parameters DMX Channel Function Type of Control Effect Decimal Percentage 1 Master Dimmer Proportional Adjusts luminous output intensity from 0 to 100 0 255 0 100 Projector Astro White Table name DMX512 F...

Page 15: ...ter Dimmer Proportional Adjusts luminous output intensity from 0 to 100 0 255 0 100 2 Spare Channel Step No effect 0 255 0 100 3 Strobe Step Open 0 20 0 8 Step Strobe speed 1 minimum frequency 21 40 9 15 Step Strobe speed 2 41 60 16 24 Step Strobe speed 3 61 80 25 31 Step Strobe speed 4 81 100 32 39 Step Strobe speed 5 101 120 40 47 Step Strobe speed 6 121 140 48 55 Step Strobe speed 7 141 160 56 ...

Page 16: ... intensity from 0 to 100 0 255 0 100 2 Dimmer Fine Proportional Fine dimmer control 16 bit 0 255 0 100 3 Strobe Step Open 0 20 0 8 Step Strobe speed 1 minimum frequency 21 40 9 15 Step Strobe speed 2 41 60 16 24 Step Strobe speed 3 61 80 25 31 Step Strobe speed 4 81 100 32 39 Step Strobe speed 5 101 120 40 47 Step Strobe speed 6 121 140 48 55 Step Strobe speed 7 141 160 56 63 Step Strobe speed 8 1...

Page 17: ... PROVISIONS OF EU LOW VOLTAGE DIRECTIVE LVD 2014 35 EU LIMITS AND METHODS OF MEASUREMENTS OF RADIO DISTURBANCE CHARACTERISTICS OF ELECTRICAL LIGHTING AND SIMILAR EQUIPMENT EQUIPMENT FOR GENERAL LIGHTING PURPOSES EMC IMMUNITY REQUIREMENTS ELECTROMAGNETIC COMPATIBILITY EMC PARTS 3 2 LIMITS LIMITS FOR HARMONIC CURRENT EMISSIONS EQUIPMENT INPUT CURRENT UP TO AND INCLUDING 16 A PER PHASE CLASS C CHANGE...

Page 18: ... difettoso Faulty product Defekte s Produkt Produit défectueux Producto defectuoso Descrizione del problema Problem found Beschreibung des Defekts Description du défaut Descripciòn del problema ________________________________________________________________________________________________________ _____________________________________________________________________________________________________...

Page 19: ...ble for delivering the appliance to an appropriate collection facility at the end of its useful lifespan Appropriate separate collection to permit recycling treatment and environmentally compatible disposal helps prevent negative impact on the environment and human health and promotes recycling of the materials making up the product For more information on available collection facilities contact y...

Page 20: ...Luci della Ribalta srl Via Berna 14 46042 Castel Goffredo mn Italy tel 39 0376 771 777 fax 39 0376 772 140 email info ldr it ...

Reviews: