PAGE 18
Set Automatic Tuning SWR Threshold
When the Z-11ProII is in fully automatic tuning mode, it begins tuning any time RF is
present, and the SWR exceeds a preset threshold. That threshold may be programmed to any
desired value between 1.5:1 and 3.0: To set the SWR threshold, press
FUNC
then
L Dn /
Thresh
. The LEDs will show the current setting of the SWR threshold. Press
FUNC
then
L Dn /
Thresh
again to advance through the possible settings.
Summary of Contents for Z-11ProII