INTRODUCTION 

LDG pioneered the automatic, wide-range switched-L tuner in 1995. From its laboratories in St. 

Leonard, Maryland, LDG continues to define the state of the art in this field with innovative automatic 
tuners and related products for every amateur need.  

Congratulations on selecting the LDG Electronics M-7700. The M-7700 provides accurate and 

precise metering for a wide range of receive and transmit parameters. While many users will choose to 
display S-meter readings on receive, and Power Output on transmit, several other useful readings are 
available.  

The M-7700 plugs into the external meter jack on the Icom IC-7700 transceiver. The parameter 

displayed on the M-7700 can be either the same as the parameter displayed on the main IC-7700 virtual 
meter, or can be independant of what is displayed on the main meter, giving the flexibility to watch two 
parameters at the same time.  

JUMPSTART, OR “REAL HAMS DON’T READ MANUALS!” 

Ok, but at least read this one section before operating the M-7700: 

1.

 

Configure the IC-7700 for normal operation. 

2.

 

Plug the M-7700 into the radio’s meter jack using the included 1/8” stereo cable. The meter jack is on 
the rear of the transceiver, between the DC Out jack and the External Keypad jack. 

3.

 

Optionally, connect a 12 volt, 250mA DC power supply to the 2.5x5.5mm coaxial power jack (center 
positive) on the rear of the M-7700. This only is needed for powering the backlight; the meter will 
function without 12V. 

4.

 

Using the radio’s setup menu, select which parameter to display on the M-7700 under the ACC menu, 
“External Meter Output” menu. 

5.

 

Operate the radio normally; the meter will continuously display the selected value. S-meter function is 
normally shown on receive, and the selected parameter on transmit. 

Summary of Contents for M-7700

Page 1: ...RATIONS MANUAL MANUAL REV A PAGE 1 LDG M 7700 External Meter for Icom IC 7700 LDG Electronics 1445 Parran Road St Leonard MD 20685 Phone 410 586 2177 Fax 410 586 8475 ldg ldgelectronics com www ldgelectronics com ...

Page 2: ...nel 4 Back Panel 5 Installation 6 Setup 7 Initial Calibration 7 Meter Parameter Selection 8 Operation 9 Application Notes 9 Base Station Use 9 Remote Use 9 Other Applications 9 Care and Maintenance 10 Technical Support 10 Two Year Transferrable Warranty 11 Out Of Warranty Service 11 Returning Your Product For Service 11 Product Feedback 2 ...

Page 3: ... can be independant of what is displayed on the main meter giving the flexibility to watch two parameters at the same time JUMPSTART OR REAL HAMS DON T READ MANUALS Ok but at least read this one section before operating the M 7700 1 Configure the IC 7700 for normal operation 2 Plug the M 7700 into the radio s meter jack using the included 1 8 stereo cable The meter jack is on the rear of the trans...

Page 4: ...ires 12VDC 250mA 2 5 x 5 5mm jack center positive GETTING TO KNOW YOUR M 7700 Your M 7700 is a quality precision instrument that will give you many years of outstanding service take a few minutes to get to know it Front Panel The front panel of the M 7700 shows seven calibrated scales S Received signal strength ID Final Output Transistors Drain Current Amps PO Transmit power output in watts SWR Tr...

Page 5: ...esired a standard headphone extension cable may be used to place the M 7700 farther from the radio The rocker switch is used to turn the internal backlight on and off It may be desirable to turn off the internal backlight when attempting to conserve battery power The brightness of the backlight may be adjusted with a small flat blade screwdriver Carefully insert the screwdriver into the hole label...

Page 6: ...etween the DC Out jack and the External Keypad jack Plug one end of the included 1 8 stereo cable into the meter jack Plug the other end of the cable into the jack marked Radio on the rear of the M 7700 If desired connect a suitable power supply 12VDC 250mA to the DC Power jack on the rear of the M 7700 using the supplied 2 5 x 5 5mm center positive power cable This power connection supplies power...

Page 7: ...down and F2 up soft buttons scroll down until the External Meter Output item is selected Rotate the main dial knob until VD is selected This displays the output drive transistor voltage which should be constant at 48 volts Press the F1 down button one more time to select External Meter Level and rotate the main dial knob clockwise until the level is at 100 percent Repeatedly press the soft button ...

Page 8: ...meter displays same as internal virtual meter S Displays signal strength on receive only PO Transmit power output watts SWR Standing wave ratio ALC Automatic Level Control COMP Voice compression ratio in dB VD Final amplifier transistor drain voltage Nominally 48VDC ID Final amplifier transistor drain current When finished selecting the External Meter Output press EXIT SET twice to return to norma...

Page 9: ...cluded 1 8 stereo connection cable provides the ability to place the meter up to several feet away from the transceiver Some obvious choices include on top or beside the radio or near the station computer Remote Use The M 7700 may be placed farther away from the IC 7700 if desired A standard 1 8 stereo headphone jack extension cable is all that is required to connect the M 7700 to the external met...

Page 10: ...the need arises Our website links you to the on line Customer Support Center where you can send us a question do your own research in the LDG Product Knowledge Books and read through lists of frequently asked product questions LDG regularly updates on line information so the best on line support information is available all day and every day The LDG website provides links to product manuals just i...

Page 11: ...eeds to be done and based on your prior instruction either contact you with an estimate or fix it and contact you with a request to pay any repair charges Please contact LDG if you have any questions before you send us an out of warranty product for repair RETURNING YOUR PRODUCT FOR SERVICE Returning a product to LDG is easy We do not require a return merchandise authorization Visit the Customer S...

Reviews: