background image

Arrow Board Operators Manual V1.2          

 

 Page 6 of 12 

 

Single Sided Arrow Board Controller –AC4S 

Arrow Board Operation 

 

Operation  

 
Once correctly set up with all 4 stabilising legs deployed, open the control box and raise the Arrow 
Board high enough so it is clear of the trailer stirrups.  
 
Rotate the sign to the desired position for viewing using the rotation locking lever. 
 
Raise the sign to the required height using the mast raise/lower toggle switch. 
 
To operate the controller, ensure that the Isolator switch is in the ‘On’ position. (There is no need to 
operate the Isolator except when servicing the unit; the isolator switch should be left in the ON 
position under normal circumstances.) 
 
The sign is operated by turning the control knob so that the pointer points to the desired mode to be 
displayed on the sign.  
 
The mode selected on the controller, will be illuminated on the sign (as viewed from the REAR of the 
vehicle). 
 
When switched from OFF to an operation mode, the sign will automatically rise to its working 
position, and the LED indicator on the control panel will light to show that the unit is in operation.  
Note: The arrow board will fully rise before the sign begins flashing the selected display. 
 
When switched OFF, after 2 seconds of inactivity, the sign will automatically lower to its travelling 
position, and the LED indicator on the control panel will go out to show that the unit is off. 
 
If the optional LED Beacons are fitted; the Beacons are controlled by the Beacons switch on the 
controller. The Beacons will be shut off under low battery conditions. Pushing the toggle to the right 
turns the Beacons on and to the left will turn them off. 

 

 

 

 

 

 

 

 

 
 

Summary of Contents for LDC ABC

Page 1: ...ors Manual V1 2 Page 1 of 12 LDC EQUIPMENT LDC AB C Size Arrow Board Installation and Instruction Manual Single Sided Arrow Board Controller Quality Management System Approved to AS NZS ISO 9001 2008...

Page 2: ...duction 3 LDC AB C Arrow Board 4 Sign Positioning 5 Inside the Control Box 5 Arrow Board Operation 6 Operation 6 Controller Operation Modes for Arrow Board 7 Fail Safe Techniques Employed 7 Troublesho...

Page 3: ...tor that provides for disconnection of power in the event that service is required or in the event of an overload The controller screen displays the current operation mode and a real time mimic of the...

Page 4: ...Page 4 of 12 LDC AB C Arrow Board AC4S Controller Single and Double sided Arrow Boards Isolator switch Optional Beacon Switch OLED Display Screen Control Knob LED Lamps with Visors Light Sensor Solar...

Page 5: ...d Deploy the stabilising legs from their travelling position horizontal to their set up position vertical by pulling out the spring loaded leg locking pin and pivoting the leg 90 degrees until the loc...

Page 6: ...l knob so that the pointer points to the desired mode to be displayed on the sign The mode selected on the controller will be illuminated on the sign as viewed from the REAR of the vehicle When switch...

Page 7: ...ime what the sign is displaying During the normal operation of the system the AC4S controller communicates continually with the Arrow Board computer requesting the current status of the Arrow Board Sh...

Page 8: ...ght sensor mounted at the bottom of the Arrow Board If the LED display on the controller does not light check the isolator switch to ensure it is in the ON or RESET position In the event of a failure...

Page 9: ...ck the wiring from the battery to the controller for poor connections Replace the battery if necessary Lamp Fault One or more lamps have failed Visually check operation of lamps check lamp connections...

Page 10: ...ing the unit DO NOT USE THE EQUIPMENT FOR ANY OTHER PURPOSE THAN IT WAS INTENDED FOR Maintenance On a WEEKLY basis perform the following activities to ensure safe trouble free operation of the equipme...

Page 11: ...r replaced for a period of 12 months Any sign that has failed as a result of a traffic accident abuse or act of vandalism or incorrect use after delivery shall not be covered under warranty provisions...

Page 12: ...onal Warning Controls Power Isolation Switch Circuit Breaker Mode Selection Switch Rotary Encoder Mode Indication LEDs 4 LEDs Beacon operation Toggle Switch Lamp Brightness 625 cd Minimum 0 0 Axis 100...