3 FRONT PANEL
1.
PROT/STBY:
This indicator shows two different statuses:
•
PROT: protection indicator. The indicator will light up orange when the amplifier is in
protection condition. Protection may be because of a short-circuit in the speaker line,
the amplifier overload and when the inside temperature is over 55ºC (131 ºF). There's
and independent protection indicator for each channel.
•
STBY: stand-by. The same indicator will light up orange when the amplifier is in stand-
by due to not detecting any sinal for more than two minutes.The indicator will switch off
when the system detects the signal again. This function is programmable through the
switch located on the rear panel.
2.
CLIP:
The clip indicator will light red when the input or output is too high. There ir an
independent CLIP indicator for each channel
3.
INPUT:
The input indicator will light green when an input signal is detected. There is an
independent input indicator for each channel.
4.
OUTPUT:
The output indicator will light green when there is an output signal. El indicador
de salida se iluminará en verde hay señal de salida. There is an independent output
indicator for each channel.
5.
POWER:
The power indicator will light blue when the equipment is on.
6.
POWER SWITCH:
It allows to switch the equipment on and off.
LDA Audio Tech - Severo Ochoa Nº 31- 29590 MÁLAGA, ESPAÑA. Tlf: +34 952028805