Appendix A: Cable section for speaker lines
This table shows the maximum advisable lenghts for 100V speaker lines. The type of cable
used to calculate them is a copper conductive twin-lead type. This can be used as planification
guide, although the appropiate final calculations for each situation are the electrician's
responsibility.
This table shows the output power of common amplification channels of 100V constant
voltage in RMS. The maximum lenght for 70V lines is half of the ones in the table.
Section
Maximum lenght with a 5% power loss
AWG
mm
mm
2
60Wrms
120Wrms
240Wrms
480Wrms
960Wrms
6
4,11
13,3
3260
1630
810
405
200
7
3,67
10,6
2600
1300
645
320
160
8
3,26
8,35
2050
1025
510
255
130
9
2,91
6,62
1625
810
405
200
100
10
2,59
5,27
1300
645
320
160
80
11
2,3
4,15
1020
510
255
130
65
12
2,05
3,31
810
405
200
100
50
13
1,83
2,63
645
320
160
80
40
14
1,63
2,08
510
255
130
65
35
15
1,45
1,65
405
200
100
50
25
16
1,29
1,31
320
160
80
40
20
17
1,15
1,04
255
130
65
35
15
18
1,02
0,82
200
100
50
25
13
Table 2: Cable section for 100V lines