IN/OUT alarm clamps
8 in put with 1 common of reference ( the in put must to pilot
at clean contacts).
1 output alarm to relay (Common, NC e NO); max. 30V, 1A.
2.4 Switches adjustment
For access to the 2 DIP-SWITCHES reverse the block of Speed dome ( pag 5) .
The DIP-SWITCH have two functions. Use for setup the switch value (Baud Rate and Protocol) and use for unit address .
Put out the camera before switches adjustment, then put on .Next table show the switch position and function .
The switch 7 and 8 of DIP Swicth 1 (SW1) be useful to setup speed of the BUS that has be common at all RS485 connect
devices:
SW
1
Baud Rate
DIP 7-8
parameter choice
Switch position
Baud Rate
Data bit
Parity
Stop bit
2400
8
No one
1
4800
(Default)
8
No one
1
9600
8
No one
1
19200
8
No one
1
The factory start up is: 4800.
1-6 Protocol
7-8 Baud Rate
1-8 address