background image

User Manual 

LCTSD318-326-336 

 

pag.

14

 

 

 

www.hrcctv.com 

 Zoom Speed: 
 Digital Zoom: 
Joystick AF/AI: 
AutoFocus Time: 
AutoIris Time: 
ALC: 
Day/Night 
Back 

 

             

Password 

 
In this menu is possible to bump up the security level if the password is enable.  

<Input PW>

:For input the password the next sub menu display .  

 

 
Before to change,input the old password.If old password is correct , cursor goes back, behind 
“input password” ,so that new password can be input . If old password is not correct,cursor goes 
back to front of “input password”.   

 

<Confirm PW>

:Confirm new password.  

<PW  protection>

:  On/Off.  Arm  or  Disarm  the  password  request  to  access  system  and  save 

Preset. 

 
Note:Default password of the system is 

123456

  

 

        

Default

 

  

 

In this menu is possible to restore factory default settings of Speed Dome.  

 

<Password>

: Arm the password protection and input user password . 

<Setup>

: Restore default and remove the configurations.  

 
 

 
 
 
 

 

          

System  reboot     

 
Select <

system reboot> 

 the dome reboot immediately to make autotest cycle.  

3.5 Lens  setup 

 
 
 
 
 
 
 
 
 
 
 

            Zoom Speed

 

 
Set the zoom speed level to high or low . 

 

             Digital Zoom

 

 
Arm <

On

> or  disarm <

Off

>  digital zoom.  

 

             Joystick AF/AI

 

Select function wanted between <

AF+AI>, < Iris>, < Focus> and <Off>. 

<

AF+AI>: 

Select this option ,camera can  put automatically mode auto focus  and electronics shutter. 

<Iris>:  Select  this  option  camera  can  put  on  mode  automatically  only  electronics  shutter,but  focus  can  also  be  manually 
controlled. (Point E) 
<Focus>: Select this option camera can  put on  mode automatically only focus up,but electronics shutter can also be manually 
controlled  . ( Point D) 
<Off>. Select this option camera do not make any automated control, that is necessary operator intervention.

 

Old PW:   ****** 

        Back 

Password:   ****** 

        Setup 
        Back 

 

Input  PW   :   ****** 

       Confirm PW:  ****** 
       PW Protection:On 
       Back 

   System 
   Lens 

       Camera 
       Pan/Tilt 
      Auto Running 
      Privacy Mask 
     Alarm 
     Exit 

 

Summary of Contents for LCTSD318

Page 1: ...LCT0804 ver 1 0 www hrcctv com ALLARMED SPEED DOME User Manual LCTSD318 LCTSD326 LCTSD336...

Page 2: ...debbono essere smaltite separatamente in altri contenitori in quanto contenenti sostanze altamente tossiche Il simbolo rappresentato in figura rappresenta il bidone dei rifiuti urbani ed tassativamen...

Page 3: ...parations 6 2 2 Brackes assembling 6 2 3 Connection 6 2 4 Switch adjustment 8 3 Menu Configuration 10 3 1 Menu Operation 10 3 2 Boot up Screen 11 3 3 Menu explanation 12 3 4 System Setup 13 3 5 Lens O...

Page 4: ...x 290mm P LCTSD318 camera Module Sony FCB EX480CP Image Sensor 1 4 type EXview HAD CCD Pixels Approx 440 000 pixels Lens 18x Zoom f 4 1mm wide to 73 8 mm tele F1 4 to F3 0 Digital Zoom 12x 216x with o...

Page 5: ...all to fix 2 Threaded inside attack 3 Drip 4 Inside custody 5 Security hook 6 Fan 7 Heating up plate 8 Hook up lever and quick shell out 9 Hook tack on of security 10 Speed Dome block off 11 Objective...

Page 6: ...ring for structure set up of Speed Dome Power 24V to alternate current Video signal the camera makes one commun composite video signal Use the RG59 coaxial cable for distance 120 m while for higher di...

Page 7: ...eo signal BNC female connector B RS485 A and RS485 B terminal box Open the screw of clamps put in the cables and close Attention to the polarity electric wires RS485 A RX and RS485 B RX in the connect...

Page 8: ...etup the switch value Baud Rate and Protocol and use for unit address Put out the camera before switches adjustment then put on Next table show the switch position and function The switch 7 and 8 of D...

Page 9: ...e complete address list For stave off accidental push down to the Speed Dome lock on the block on the security hook After to have finish the connection and adjustment necessary close the access door o...

Page 10: ...is possible to manage and setup the Speed Dome 3 1 Menu Operation Use the console Joystick or the HR DVR directional key up and down to move in item of menu Use right Joystick or the HR DVR directiona...

Page 11: ...the screen until booting success Protocol display the protocol in use set up by DIP Switch 1 Com display the parameter of communication set up by DIP Switch 1 address display the Speed Dome address as...

Page 12: ...and restrict 4 Cruise Pattern Record Test and bootup 4 Pattern Zona Zone name identification and passage speed Park time 1 255 Off Park action Preset Pattern 1 4 Cruise 1 4 Tour 1 4 Aree privacy setup...

Page 13: ...e Pattern name up to display Zoom On Off To display the zoom Orientation On Off To display the rotation degree Alarm Name On Off To display current Zone Name Mask On Off To display the zone name mask...

Page 14: ...n and input user password Setup Restore default and remove the configurations System reboot Select system reboot the dome reboot immediately to make autotest cycle 3 5 Lens setup Zoom Speed Set the zo...

Page 15: ...s a color camera Use this option in light environment 3 6 CAMERA Camera Setup Sensibility In This menu is possible to change setup time of the shutter to get the light that has to pass on the CCD sens...

Page 16: ...commands Note Do not put in the function with protocol Pelco PD Speed Amplify The speed of Dome is mush lower with some protocols control In this menu is possible set speed amplify to accelerate dome...

Page 17: ...Test The current preset test Next Test The next preset test Remove current Select to delete the current preset Tour Select Tour To enter sub menu and make on or adjustment 4 Tours Tour Number Set tou...

Page 18: ...nd passage speed Zone Number Select zone name Name Put desired zone name Left limit In here move the camera to the desired left limit Right limit In here move the camera to the desired right limit Rem...

Page 19: ...e masking zone Before to mask make sure with camera just be position to the cover zone Up on in menu is not possible to move the dome Mask Remove Remove current mask All Remove Remove all mask zone 3...

Page 20: ...ut alarm Alarm In 1 8 For each input alarm is possible associate preset or select 1 to the 4 tour cruise or pattern setup Output 1 ON OFF Select arm disarm output relay Arm Disarm Arm or disarm the al...

Page 21: ...N ON ON 71 ON ON ON ON 72 ON ON 73 ON ON ON 74 ON ON ON 75 ON ON ON ON 76 ON ON ON 77 ON ON ON ON 78 ON ON ON ON 79 ON ON ON ON ON 80 ON ON 81 ON ON ON 82 ON ON ON 83 ON ON ON ON 84 ON ON ON 85 ON ON...

Page 22: ...7 ON ON ON ON 198 ON ON ON ON 199 ON ON ON ON ON 200 ON ON ON 201 ON ON ON ON 202 ON ON ON ON 203 ON ON ON ON ON 204 ON ON ON ON 205 ON ON ON ON ON 206 ON ON ON ON ON 207 ON ON ON ON ON ON 208 ON ON O...

Page 23: ...tv com pag 23 Technical specifications can be modified without any preliminary notice This manual may not be reproduced in whole or in part except brief quotations in articles or magazines without the...

Page 24: ...2601 TORINO sede operativa Via G B Feroggio 10 10151 Torino ITALIA Tel 39 011 453 53 23 Fax 39 011 453 70 49 SHANGHAI ufficio di rappresentanza Minhang Residence Room 506 N 50 Jinzhu Road 200336 Shang...

Reviews: