background image

2

Scope of delivery

LCN-GT6  (LCN-GTS6),  mounting  plate,  2  screws    3,2  x  15mm  &    inlay  sheet  (blank).

How it functions

The   

sensor keys 

of the LCN-GT6 (LCN-GTS6) react to a touch on the glass surface. 

Depending on the duration of touch, an appropriate  LCN-control command (

Hit, L

ONG

 or  

R

ELEASE

) will be sent. When no changes are made to the default key settings, (see page 5: 

Key mapping), the keys work on the A  table according to their numbering.  

There is the possibility to trigger off  2 

additional keys, 

through touching two keys at  

the same time. Key A1+A6=D7 and  A2+A5=D8.
This kind of double touching is especially suitable for functions, that should not be 
accidentally triggered.  (central-off, switching the alarm system, etc)

The  integrated  

temperature sensor  

supplies  the measured values with a triggering from

 

 

0,1°C,  and  thanks to its adaptive  average calculation, practically  noiseless. 

The 6 

Status-LED´s

 in the sensor areas are individually controlled over the T-Port and 

configured over the LCN-PRO (O

N

, O

FF

, B

LINKING

, F

LICKERING

). 

An external power supply is needed when operating the 

key background LED´s

 and the  

®

Corona -surrounding  light 

  (please  order  LCN-NUI  seperately). The  application  of  a 

power supply is also meaningful with a brighter environment; It increases the brightness of 
all the  LED´s on the  LCN-GT6  ( LCN-GTS6 ).

LCN-GTS6

®

   Installation guide 

LCN-GT6

®

Summary of Contents for LCN-GTS6

Page 1: ...NUI required and can be switched as a decent orentation light so that the LCN GT6 LCN GTS6 can also be operated in darkness The 6 capacitive working sensor keys are situated behind a 5mm thick glass front A soft touch to the surface is enough to trigger off the functions The captions on the sensor keys can be carried out individual ly per inlay and can be changed anytime without difficulty 6 keys ...

Page 2: ...ouble touching is especially suitable for functions that should not be accidentally triggered central off switching the alarm system etc The integrated temperaturesensor supplies the measured values with a triggering from 0 1 C and thanks to its adaptive average calculation practically noiseless The 6 Status LED s in the sensor areas are individually controlled over the T Port and configuredover t...

Page 3: ...nal LCN GRT The LCN GT6 must not wobble on the wall as this would lead to false triggering That is why when installing the edges of the cavity wall mounted box should be counter sunk or the flush mounted box should not be surmounted on the wall to guarantee a flawless function of the LCN GT6 LCN GTS6 Corona surrounding light O Light Orientation light and the blue key Note Important When the temper...

Page 4: ...ssigned in the LCN PRO menu Ports The assignments can be comfortably chosen as graphics For example each line of 3 keys can be changed into 2 larger keys see the lower example Important functions can be easily operated without losing the flexibility of many keys T Ports Change mapping LCN GT6 LCN GTS6 will be automatically recognized from the module and the temperature registered in the variable 3...

Page 5: ... the connected UP x module onto the wall At the bottom area the LCN GT6 must be hooked into the corners of the mounting frame and pressed towards the wall Through pushing in the plastic slider on the side the LCN GT6 is locked firmly onto the mounting frame LCN GT6 LCN GTS6 Installation LCN GTS6 Installation guide LCN GT6 IG1 LCN ISSENDORFF Oben adjusting the mounting frame green help for insertio...

Page 6: ... ideal luminance of the status LED s Inserting the inlay into the key sensor Pull the plastic slide to the side outwards at the rear of the key sensor Insert the inscripted inlay at the bottom side of the LCN GT6 LCN GTS6 into the groove until it resists Tip If you cut off the corners of the inlay around 2 mm it will make it easier for inserting the inlay into the groove When changing the paper re...

Page 7: ... to the I Port of any module with year of manufacture 2013 or later and supplies theT Port over the module The brightness of the status LED s as well as the Corona surrounding light can be reduced for the night operation with the command LED control LED brightness Captions for the keys using ordinary paper and operation without an LCN NUI make the LED s harder to recognise by direct exposure to li...

Page 8: ...ey background LED s blue funktions OFF ON white corona LED s controllable over command GT brightness adjustable in steps temperature sensor measurement range Installation dimensions W x H x D 90mm x 90mm x 12 5mm 5mm glass thickness LCN GT6 75mm x 75mm x 10 5mm 3mm glass thickness LCN GTS6 operating temperature 10 C to 50 C air humidity max 80 rel non condensing environmental conditions use as sta...

Reviews: