background image

 

75.5318.00   20080111 

 

Page 2 of 9 

SAFETY 
PRECAUTIONS 

MECHANICAL 
INSTALLATION- 
PREPARING AND 
MOUNTING THE 
SENSOR 

 

CAUTION

:  REMOVE THE MASTER AND ALL SLAVE CIRCUIT BOARDS FROM THE ALUMINUM 

                     EXTRUSION BEFORE PERFORMING ANY DRILLING.  WHEN COMPLETE, ENSURE 
                     THAT ALL METAL SHAVINGS ARE CLEANED FROM THE EXTRUSION BEFORE  
                     RE-INSERTING THE CIRCUIT BOARDS.

 

  Shut off all power going to the header before attempting any wiring procedures. 

  Maintain a clean & safe environment when working in public areas. 

  Constantly be aware of pedestrian traffic around the door area. 

  Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected 

reactions by the door. 

  Always check placement of all wiring and components before powering up to ensure that moving door parts 

will not catch any wires and cause damage to equipment. 

  Ensure compliance with all applicable safety standards (i.e. ANSI A156.10 / 19) upon completion of installation. 

 

 
 

1. 

Install push or pull arm. 

 
2. 

Remove the screw that secures the end cap to the Door Mounted Safety Sensor extrusion (as shown in Picture 1 below). 

 

 
 
 
 
 
 

 
 
 

3. 

Remove the plastic lens by pulling the lens out from the top of the extrusion (as shown in Picture 2 above). Do not use a 
screwdriver to pry the lens, as cracking may occur. 

 

 
 
 
 

 
 
4. 

Picture #3 below shows the angle adjustment clip in its proper position within the extrusion (PCB’s are removed, and clip 
is shown at end of extrusion for clarity only). To remove the clip, simply pull the tab out away and downward from the 
extrusion, then rotate the module out from extrusion as shown in picture #4. To re-install, simply reverse the procedure -
the PCB must first be installed into the adjustment clip, then installed into the aluminum extrusion.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

IMPORTANT NOTE:  The end of the extrusion that is towards the pivot end of a center hung door, should be in far  
                                   enough from the edge of the door, as shown in picture #5, to prevent the end cap of the DMSS 
                                   from rubbing against the finger guard during door movement.  Pay particular attention on the safety 
                                   side of the door.  Hinge hung doors will not require as much clearance between the end of the DMSS 
                                   and hinge-side jamb as shown in picture #6 below.  At the leading edge of the door the edge of the 
                                   DMSS, including the end cap, should be as close as possible to the leading edge of the door without 

creating mechanical interference with the door jamb or with an adjacent door (pairs).

!

CAUTION

NOTE:  If a brick store front is encountered during installation, route the sensor wiring through the door header. 

Summary of Contents for 8310-804

Page 1: ...ld this angle be interrupted detection will occur Detection is NOT based upon the intensity of the beam and in principle will not be affected by the color or background of the object that interrupts t...

Page 2: ...sion as shown in Picture 2 above Do not use a screwdriver to pry the lens as cracking may occur 4 Picture 3 below shows the angle adjustment clip in its proper position within the extrusion PCB s are...

Page 3: ...to the safety side as shown below Again be sure not to drill through any through bolts or braces within the door A cutaway view below Picture 13 shows wire passage through the door Picture 12 and 14 s...

Page 4: ...0 may be completed Wiring will vary according to the application Available positions on the connector are shown below TERMINAL EXPLANATION OF WIRING CONNECTIONS 1 TST TEST DATA Used with SMR systems o...

Page 5: ...he DMSS lens may then be installed to fit tight against the end cap and plastic sheath to hold it in place as shown in picture 24 Leave the end cap off at the opposite end until all mechanical adjustm...

Page 6: ...is jumper set to Normal Mode Power the sensors up with 12 to 24 VAC 10 or 12 to 24 VDC 10 LED status should reflect what was configured for the relay output Use a white gray or black piece of cardboar...

Page 7: ...complete solution For more information visit www lcn ingersollrand com Door Mounted Safety Sensor does not work at all No LED indications Faulty power supply Faulty connections Power supply must be 12...

Page 8: ...75 5318 00 20080111 Page 8 of 9 APPENDIX WIRING DIAGRAMS...

Page 9: ...75 5318 00 20080111 Page 9 of 9 APPENDIX WIRING DIAGRAMS Cont d...