DESCRIPTION
TECHNICAL
SPECIFICATIONS
INSTALLATION
TIPS
The sensor must be
firmly fastened to
prevent v bration.
COMPONENT ID
The Door Mounted Safety Sensor (DMSS) (8310-804) detector is a door-mounted presence detection system that is used on
automatic pedestrian swing doors. Unlike other door-mounted sensing devices, the sensors unique electronic architecture allows
the detection modules to be mounted near the top of the door, out of harm's way. A rotating cam is used for the range adjustment
of the detection zone. Width patterns may be altered by adding slave modules to the master module. These slave modules are
simply added by inserting them into the aluminum extrusion, then connecting them with the attached flat ribbon cable to the next
module without interrupting other modules in the same extrusion. Once installed, the detection zone (in addition to being
adjustable for distance) can be angled independently from the other modules.
Each DMSS module consists of two optics, a transmitter (TX) and a receiver (RX), and functions independently of the other
modules. The transmitter emits an extremely precise beam, which measures approximately 4" in diameter at a distance of 8'.
The receiver, in turn, receives the infrared beam reflected off of the floor. This transmission and reception forms a detection
triangle, which is the basic premise of detection (called triangulation). Should this angle be interrupted, detection will occur.
Detection is NOT based upon the intensity of the beam, and in principle will not be affected by the color or background of the
object that interrupts the angle.
DESCRIPTION
SPECIFICATION
Power Supply
12 to 24 VAC ± 10% / 12 to 24 VDC + 10%
Current Consumption:
Master: On = 60 mA max. / Master: Off = 30 mA max.
Slave: On = 40 mA. Max. / Slave: Off = 30 mA max.
Input Inhibit
12 to 24 VAC ± 10%: / 12 to 24 VDC + 10% / Inhibited when voltage is applied
SMR Input Data
12-18 VDC: Inhibited when voltage is applied
Output Interface; relay
Relay; max. contact rating is 1A @ 30v ( resistive)
Detection Range
0' to 8'
Distance Adjustment
2’ to 8’ / Rotating cam with linear adjustment
Max. Mounting Height
8’
Detection Time
< 50 ms
Detection Signal Duration
Infinite Presence Detection
Output Hold Time
Potentiometer Range: 0.1 to 4.5 seconds.
LED Indications
Master: Red LED = Detection
Green LED = Active Output
Slave: Red LED = Detection
Operating Temperature Range
-30° F to 140° F
PCB Dimensions
Master: 10.91" x 1.5"
Slave: 8.75" x 1.5"
Connection to Door Controller
8 Position Screw Terminal on Master PCB
Connection: Master to Slave
Flat R bbon Cable With Connectors and Key Lock
Max. Number of Slaves
Standard = 9 / With Monitoring = 8 max.
Functions Selection
Detection Mode - NO or NC
Normal Mode or Background Analysis Mode
Sensor must be in a location
that does not interfere with door
hardware (finger guards, lock
rods, etc.).
The sensor must not
have any unwanted
objects likely to move or
vibrate in its path.
DOOR MOUNTED
SAFETY SENSOR
DMSS
Quick Disconnect Cable
(8310-847)
Jamb Cap (2)
8310-804 DOOR MOUNTED SAFETY SENSOR
USER’S GUIDE