Door closer with electronic release & Multi-point hold open

4310ME Series

Installation Instructions

Closer Installation

1a  Closer Information

Closer is handed at the factory. The hand of the closer must match 

the hand of the door (see the door handing diagram below).

1b  Voltage

Voltage supplied to the door frame MUST match voltage of the 

solenoid.

1c  Before beginning this step, determine which type of 

wiring option will be used, and follow the 

corresponding instructions:

Concealed Wiring:

 see Figure 3 on page 3.

a.  Prepare the frame per the 

proper template on page 

4. Be sure all the holes are 

dimensioned correctly before 

drilling and tapping.

b.  Assemble the conduit 

connector provided to the 

flexible conduit, then attach to 

the hole in the mounting plate.

c.  Secure the mounting plate 

to the frame with the screws 

provided.

Surface Wiring:

 see Figure 4 on 

page 3.

 

L

NOTE: Remove the knockout in the top of the cover.

a.  Prepare the frame per the proper template on page 4. Be sure 

all the holes are dimensioned correctly before drilling and 

tapping.

b.  Secure the mounting plate to the frame with the screws 

provided.

c.  Attach the surface run 

Z\x

” EMT conduit to the hole in the 

bracket on the mounting plate. Be sure the conduit is securely 

attached to the bracket.

1d  Wiring Connections

Make the wiring connections at this time. Connect the two black 

wires to the input voltage (polarity is not important). The green wire 

MUST be connected to an earth ground (see Figures 3 & 4 on page 

3).

1e  Spacer/Arm

Place the spacer on the closer shaft, slide the arm onto the closer 

shaft, and secure it with the arm shaft screw (see Figure 1 on page 

3).

1f  Track Roller

Insert the track roller into the track, and end caps into both ends of 

the track. Place track plugs in the track where needed. Using the 

fasteners provided, mount the track on the door per the template on 

page 4.

1g  Set Screw

Loosen the set screw in the end of the arm, open the door 

approximately 30˚, pull the arm over the top of the door and 

connect to the track roller. Tighten the set screw firmly.

1h  Electric Checkout

Regulate the closer and perform an electrical checkout, as 

instructed on page 2, before installing the closer cover.

1i  Disengage the Swing Free Arm

To disengage the swing-free action of the arm, insert the locking 

screw (stored in the tube portion of the arm) into the shaft end of 

the arm, and tighten securely.

!

 WaRNiNg 

!

!

HaZaRDOUS VOLTagE 

CaN SHOCK aND CaUSE 

SEVERE iNJURY

Disconnect power before 

making any electrical 

connections or performing 

maintenance.

HOW TO TELL HAND OF DOOR:

LEFT
HAND
DOOR

RIGHT

HAND

DOOR

MAXIMUM OPENING FORCE

=

33 ft-lbs

45 N-m