additif ST GB 

 

05/01/2007 

LCJ CAPTEURS - ZA le Chêne Férré 44120 VERTOU – Tel 33.(0)2.40.05.08.55 – [email protected] 

CV3F-ST Option 

 

   

 

 

Connect blue wire « rotavecta » to terminal B of the ST connector block 

Connect red  wire « rotavecta » to terminal R of the ST connector block  

 

Connect the 12V (10 to 14) supply. Blue - / Brown + 

 

Connect the coaxial cable of the CV3F sensor correctly connecting the core and screening. 

 

Power up the instrument then follow the procedure in the “User calibration” of display 

user manual  

 

Connect the display receiver equipment to the NMEA connector: 

 

 

 

- for the COM(1) port of an RS232 computer 

 

connect Rx  terminal 2 of COM1  

to the AUX connector block terminal A 

connect 0V  terminal 5 of COM1  

to the ALIM (SUPPLY) connector block terminal 0V 

 

if necessary, connect terminals 6 and 7 of COM1 together. 

   PC SUBD 9 terminal    

      COM1 type   connector -  Soldering side 

 

 

- for a floating RS422 standardised NMEA 183 input 

 

Make sure in advance that none of the receiver inputs is attached to 0 Volts, otherwise use the  RS232 type connection. 

 

connect terminal A of the AUX connector block to +Ve ( or In +)  or A of the NMEA display 

connect terminal B of the AUX connector block to -Ve ( or In -)  or B of the NMEA display 

 

 

 

 

 

 12 V 

 

 

              0 V   Blue 

 

 CV3F Core 

       Screening 

 

 OUT   + NMEA 

 

 OUT  - NMEA 

                      
                  Red  “Rotavecta” ST60 
                  Blue “Rotavecta” ST60 

 

 

L=131mm 

 

W=58mm 

H=37mm 

 

   1      2      3      4      5 

   6      7      8     9 