Rev: 11.27.19
Page 8
CCD-0002711
Electrical
Since there are no field-serviceable parts in the motor of the 12V DC motor, electrical troubleshooting and
service is limited to replacing only those components as previously outlined.
NOTE:
Thorough inspection of wiring and connections is the only other electrical service that can
be performed.
Syncing the Slide-Out
When the two opposing sides of the slide-out are misaligned—out-of-sync—an adjustment can be made to
realign—sync—the system by performing a manual adjustment of the outer x-shaft.
Fig. 4
A
B
C
Motor End
Always disconnect battery from system prior to manually operating system. Failure to disconnect
battery can cause electricity to back feed through the motor and cause serious damage to the
system as well as voiding the warranty.
Before accessing the power unit, make sure power to the system has been disconnected.
The slide-out adjustment for syncing the LCI Above Floor Slide-out is handled through the drive shaft (Fig. 2).
To sync the slide-out system, do as follows:
1.
Access the slide-out's drive slide rail assembly (motor end) (Fig. 2).
NOTE:
The slide-out shaft will be accessible from the inside of the unit. The slide-out motor and mechanism
are accessible from the outside.
2.
At the motor end, remove the 1/4" - 20 bolt (Fig. 4A) and locking nut (Fig. 4B) from the outer x-shaft
(Fig. 4C).
NOTE:
This is the part that allows the follow slide to be adjusted, pulling the room closer to or further away
from the wall at the follow end.