background image

 

 

No response to the sound

1.

 

Make sure the fixture does not receive DMX signal 

2.

 

Check microphone to see if it is good by tapping the microphone. 

 

One of the channels is not working well: 

1.

 

The stepper motor might be damaged or the cable connected to the PCB is 
broken 

2.

 

The motor’s drive IC on the PCB might be out of condition. 

 

9

.  

FIXTURE CLEANING

 
The cleaning of internal must be carried out periodically to optimize light output.  
Cleaning frequency depends on the environment in which the fixture operates: damp, 
smoky or particularly dirty surrounding can cause greater accumulation of dirt on the 
fixture’s optic. 

 

 Clean with soft cloth using normal glass cleaning fluid. 

 

Always dry the parts carefully 

 

Clean the external optics at least every 20 days.  Clean the internal optics at least 
every 30/60 days.

 

Summary of Contents for LCG-027A

Page 1: ...1 LED WALL TRI LCG 027A User Manual Please read the instructions carefully before use ...

Page 2: ...s must be replaced if they are visibly damaged Do not allow children to operate the unit Replace fuse only with the same type Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Disconnect the mains power if the unit is not used for a long time Do not look directly at th...

Page 3: ...120V 60Hz Size 32 15 x 21 5 x 19 2 cm Weight 5 0 kg 4 OPERATIONS 1 BUILT IN Program a Press MODE button Pr b Press UP or DOWN button select the effect program Pr 01 Pr 10 When LED display show Pr 01 press SETUP button enter the static color edit press UP or DOWN button to choose the 7 kinds of static color 1 r 2 rg 3 g 4 gb 5 b 6 rb 7 rgb when it shows 7 rgb press the SETUP to adjust the brightnes...

Page 4: ...auto run 9 kinds of built in program Pr 02 Pr 1 The user can set up the running speed the strobe speed under the built in program Pr 02 Pr 10 then it will run according to the program which has been set up 3 DMX mode A Press MODE button enter DMX mode menu d xxx B Press UP or DOWN button setup DMX address d 001 d 512 C Press SETUP button setup DMX mode menu X ch D Press UP or DOWN button setup DMX...

Page 5: ... 1 0 255 Master Dimmer 2 0 255 Red 3 0 255 Green 4 0 255 Blue DMX MODE 4 4 CHANNELS 4C 2 CHANNEL VALUE FUNCTION 1 0 255 Master Dimmer 2 0 255 Red 3 0 255 Green 4 0 255 Blue DMX MODE 5 6 CHANNELS 6C CHANNEL VALUE FUNCTION CH1 0 255 Master Dimming Red adjustment 0 255 Red color dimming Choose the static color it is available when the 6 0 8 R255 9 17 R255 G50 18 26 R255 G150 27 35 R255 G255 ...

Page 6: ... 188 R50 G220 B100 189 197 R150 G220 198 206 R150 G220 207 215 G180 B220 216 224 G220 B50 225 233 R220 G100 B50 234 242 R220 G200 B100 243 251 R255 G200 B150 252 255 R255 G255 B255 Speed adjustment control the CH6 26 255 speed 0 255 0 255 slow fats CH3 0 255 Green adjustment CH4 0 255 Blue adjustment CH5 0 9 NO FUNCTION 10 255 STROBE slow fats 0 25 In CH2 can choose 29 kinds of static color 26 51 ...

Page 7: ... blue gradual change 4 MASTER SLAVE MODE Press MODE button enter slave mode SLAV The effect program of the master light on Built in program or auto run mode is the same with the slave light 5 DMX512 CONNECTIONS The DMX512 is widely used in intelligent lighting control with a maximum of 512 channels 1 3 2 1 3 2 INPUT OUTPUT COMMON DMX DMX DMX 512 120 OHM 1 4W ...

Page 8: ...0 seconds the LED display will be close if touch any button at this time the LED display will be recover the original status All the button will be recover the function B This fixture have the excess temperature self defective function When the brightness is obvious reduce please check if the fan work in normal after clear the trouble clear please power supply the light will be release defend and ...

Page 9: ...B might be out of condition 9 FIXTURE CLEANING The cleaning of internal must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture s optic Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully ...

Reviews: