Symbol

Equipment

Status

Description

on

battery working

off

no battery connected

slow flash

low voltage

quick flash

over voltage

on

daytime

off

nighttime

slow flash

charging

quick flash

over tempreture, stop charging

off

load off

on

load work with 100% power

flash for 3 times

load work with 75% power

flash for 2 times

load work with 50% power

flash 1 time

load work with 25% power

battery

solar panel

load

 
 

LED display 

   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Remark:    Slow flash frequency is about 2 times/s, quick flash frequency is about 2 times/s. 

 

Output mode 

The controller can automatically detect day/night through testing the open circuit voltage of the solar panel, no 

setting of a clock is required. It gets the dawn light start time through learning to daytime and nighttime in different 

area or season. 

        There are 4 output modes available: 

 

Light  control  “on”  and  time  control  “off”  (1-4.):  Load  starts  working  when  controller  detects  night  and  stop 

working as set time (the load stops working if controller detects “daytime” no matter the set time is achieved or 

not); 

Summary of Contents for LCCD-A1

Page 1: ...USER MANUAL LCCD A1 Solar Controller LED Driver Built in Timer 20120314 VERSION 1...

Page 2: ...learning function easily realizing automatically lights on in the morning With electricity protection data saving function Complete protections on reverse polarity battery or solar panel over charge o...

Page 3: ...t direction regularly Installation steps connection diagram Firstly connect load with controller and then wire battery and solar panel to controller respectively please pay attention to the distinctio...

Page 4: ...LED display Remark Slow flash frequency is about 2 times s quick flash frequency is about 2 times s Output mode The controller can automatically detect day night through testing the open circuit volta...

Page 5: ...ch mode Image on tens digit Model Image on unit digit Parameter Load work with 100 power Work period 0 14hours Load work with 75 power Work period 0 14hours Load work with 50 power Work period 0 14hou...

Page 6: ...mode 1 5 Confirm Press to enter setting mode nixie tube unit digit would flash skip press to chose the expected output mode parameter confirm press to confirm and exit the setting mode 2 Under browse...

Page 7: ...otec on Reconnect voltage 12V 24V Overvoltage protection 16V 32V Max panel voltage 55V Temperature compensation 4mV 2V Self consumption 5 10mA Day night detect voltage Day 9V night 7V Day night detect...

Page 8: ...in daytime Solar panel wiring problem Make sure the wiring between controller and solar panel is correct Solar indicator on in nighttime without load output System cannot detect night System detects n...

Reviews: