12V system

24V system

LED driver output voltage range

16V~70V

32V~70V

Recommended series LED lamp qty.

5~20PCS

10~20PCS

LED load max. power

30W

60W

 

Recommended minimum wire size: 2.5mm²; 

 

Controller be with Reverse Current Protection by MOSFET which inspects the current direction regularly; 

 
Installation steps & connection diagram 

 

Firstly  connect  load  with  controller  and  then  wire  battery  and  solar  panel  to  controller  respectively;  please  pay 

attention  to  the  distinction  of  negative  and  positive;  After  connecting  the  battery,  controller  will  automatically 

recognize system voltage and display on the nixie tube. (“12” stands for 12V system, “24” stands for 24V system.) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Accepted LED load 

User should make sure the LED load can meet following standards 

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for LCCD-A1

Page 1: ...USER MANUAL LCCD A1 Solar Controller LED Driver Built in Timer 20120314 VERSION 1...

Page 2: ...learning function easily realizing automatically lights on in the morning With electricity protection data saving function Complete protections on reverse polarity battery or solar panel over charge o...

Page 3: ...t direction regularly Installation steps connection diagram Firstly connect load with controller and then wire battery and solar panel to controller respectively please pay attention to the distinctio...

Page 4: ...LED display Remark Slow flash frequency is about 2 times s quick flash frequency is about 2 times s Output mode The controller can automatically detect day night through testing the open circuit volta...

Page 5: ...ch mode Image on tens digit Model Image on unit digit Parameter Load work with 100 power Work period 0 14hours Load work with 75 power Work period 0 14hours Load work with 50 power Work period 0 14hou...

Page 6: ...mode 1 5 Confirm Press to enter setting mode nixie tube unit digit would flash skip press to chose the expected output mode parameter confirm press to confirm and exit the setting mode 2 Under browse...

Page 7: ...otec on Reconnect voltage 12V 24V Overvoltage protection 16V 32V Max panel voltage 55V Temperature compensation 4mV 2V Self consumption 5 10mA Day night detect voltage Day 9V night 7V Day night detect...

Page 8: ...in daytime Solar panel wiring problem Make sure the wiring between controller and solar panel is correct Solar indicator on in nighttime without load output System cannot detect night System detects n...

Reviews: