Install the Transformer

1A

CROSSBAR

#8-32 FLAT
HEAD SCREW

Remove the two #8-32 flat head screws to remove the

crossbar.

1

1

1

1B

#8-32
SCREW

CROSSBAR

Mount the crossbar to the electrical box with the provided

two #8-32 screws.

2

2

2

CAUTION:

Turn the power to electrical box off!

1D

Slide the transformer onto the crossbar.

Align the transformer holes with the crossbar holes; replace

and tighten the two #8-32 flat head screws.

6

#8-32
SCREW

7

7

7

6

1C

SAFETY WIRE

CROSSBAR
BRACKET

4

5

5

Hook the transformer safety wire onto the backplate bracket.

Connect the backplate to a suitable ground in accordance with

local electrical codes.

For each set of power line wires, connect the hot and neutral

wires to the black and white transformer wires, respectively.

3

4

5

NOTE:

All transformer power line wires must be

connected to the same phase.

3

Summary of Contents for TRANSDIR-SFE300

Page 1: ...tant Safety Information on next column before proceeding with the installation The dimmer must be derated as indicated by the dimmer manufacturer Important Safety Information Do not conceal or extend bus bar conductors through a building wall Do not install this lighting system in a damp or wet location To reduce the risk of fire and burns do not install this lighting system where the uninsulated ...

Page 2: ...sbar Align the transformer holes with the crossbar holes replace and tighten the two 8 32 flat head screws 6 8 32 SCREW 7 7 7 6 1C SAFETY WIRE CROSSBAR BRACKET 4 5 5 Hook the transformer safety wire onto the backplate bracket Connect the backplate to a suitable ground in accordance with local electrical codes For each set of power line wires connect the hot and neutral wires to the black and white...

Page 3: ... should be installed to support the 2 Circuit Monorail while connecting 2 Circuit Monorail to the surface mount transformer Refer to the instructions provided with the standoffs 1 2 3 2B Place a 2 Circuit Monorail section into the standoffs and power feed housings Screw the power feed cap completely to the power feed housing Make sure that the power feed cap is not cross threaded 4 5 POWER FEED CA...

Page 4: ...ghting com 2008 LBL Lighting All rights reserved The LBL Lighting graphic is a registered trademark of LBL Lighting LBL Lighting reserves the right to change specifications for product improvements without notification A Generation Brands Company SAVETHESE INSTRUCTIONS ...

Reviews: