Installation Instructions for

1.3

TRANSDIR-SFE300_-2

980MR2DSFE30SMT

1

2-Circuit Monorail

12 Volt 300 Watt Single Direct Power Feed
Electronic Surface Mount Transformers

CAUTION - RISK OF FIRE

This product requires installation by a qualified
electrician. Before installing be sure to read all
instructions and DISCONNECT POWER TO
THE ELECTRICAL BOX.

GENERAL PRODUCT INFORMATION:

This product is ETL listed and suitable only for indoor dry locations

and approved for use at any height above the finished floor.

A typical installation is shown. Specific installation must be in

accordance with local electrical codes.

This product may be dimmed only with a low voltage electronic

dimmer. Using a dimmer not designed for low voltage electronic

applications may work initially, but could eventually cause

transformer failure and will void the warranty.

This product is intended for use with LBL Lighting low voltage

lighting systems only.

Read all instructions thoroughly. Read "Important Safety

Information" on next column before proceeding with the

installation.

The dimmer must be

derated as indicated by the dimmer manufacturer.

Important Safety Information

Do not conceal or extend bus bar conductors through a building
wall.

Do not install this lighting system in a damp or wet location.

To reduce the risk of fire and burns, do not install this lighting
system where the uninsulated open bus bar conductors can be
shorted or contact any conductive materials.

To reduce the risk of the system overheating and possibly causing a
fire, make sure all the connections are tight.

Do not install fixture assemblies closer than six inches to curtains
or similarly combustible materials.

Turn the electrical power off before modifying the lighting system in
any way.

The fixtures used with the system must be identified to be used
with the corresponding system.

Minimum volume of the electrical box must be 6 cubic inches (98
cubic centimeters).

Load the circuit of the surface mount transformer to no more than
the maximum rated capacity as specified.

To reset the electronic surface mount transformer, turn the power
off then on (main power, breaker panel, or wall switch).

Summary of Contents for TRANSDIR-SFE300

Page 1: ...tant Safety Information on next column before proceeding with the installation The dimmer must be derated as indicated by the dimmer manufacturer Important Safety Information Do not conceal or extend bus bar conductors through a building wall Do not install this lighting system in a damp or wet location To reduce the risk of fire and burns do not install this lighting system where the uninsulated ...

Page 2: ...sbar Align the transformer holes with the crossbar holes replace and tighten the two 8 32 flat head screws 6 8 32 SCREW 7 7 7 6 1C SAFETY WIRE CROSSBAR BRACKET 4 5 5 Hook the transformer safety wire onto the backplate bracket Connect the backplate to a suitable ground in accordance with local electrical codes For each set of power line wires connect the hot and neutral wires to the black and white...

Page 3: ... should be installed to support the 2 Circuit Monorail while connecting 2 Circuit Monorail to the surface mount transformer Refer to the instructions provided with the standoffs 1 2 3 2B Place a 2 Circuit Monorail section into the standoffs and power feed housings Screw the power feed cap completely to the power feed housing Make sure that the power feed cap is not cross threaded 4 5 POWER FEED CA...

Page 4: ...ghting com 2008 LBL Lighting All rights reserved The LBL Lighting graphic is a registered trademark of LBL Lighting LBL Lighting reserves the right to change specifications for product improvements without notification A Generation Brands Company SAVETHESE INSTRUCTIONS ...

Reviews: