9
Function
Pressing the Function button, will enable the auxiliary functions, marked
with a blue color on the buttons. The function icon letter ‘F’ will appear in
the lower right corner of the display.
Enter /
Esc
The Enter / Esc button is used to confirm a input, or to leave a menu.
Hold /
Copy
When “HOLD” is pressed, the sweep position indicator stops at the current
position and freezes the screen. In “HOLD” mode the frequency sweep is
stopped and depending on the setting of Oscillator, the RF is either On or
Off. (see menus)
The “COPY” key will write the screen contents to the built-in storage drive.
The “COPY” function will create a file and directory according to the settings
in the ’Preset Measurements (04)’ menu. During write to storage the ’C’ icon
letter is lit, and when ‘C’ disappears it is safe to access the storage drive
through the USB connector.
Dot / Marker
The dot button becomes active when entering new numeric sweep
parameters.
The Marker button is active when the instrument is in measurement mode,
and is used to enable the marker function.
Arrows
The arrows keys are used for adjusting the position of the markers. When
the X-axis is highlighted they operate as left and right, and when the Y-axis
is highlighted they operate as up and down keys.
Mode /
Menu
The mode button switches between the various measurement modes, as
configured in the ‘Display mode select (01)’ menu.
The Menu button enters the menu system.