Platinum Luxury-Lift
®
Additional Operating Features
Power Supply Over-Current Protection
The Platinum series lift chairs are equipped with over-current protection. This feature prevents damage
to the motors and electronics if there is an overload, short circuit or ground fault. Should the system
detect an over-current, the system shuts down and the chair stops functioning.
If the over-current protection is activated, stop pressing the button or toggle in use. The system should
reset automatically. If you believe the chair is not being overloaded, or experiencing a short circuit or
ground fault, you may restart the function of the chair after the button or toggle has been released.
Should the over-current protection trip repeatedly, refer to the
Troubleshooting
section in this manual.
Additionally, the power supply includes a green LED status light to indicate power is being supplied
to the system. If the light is
not
illuminated, no power is being supplied to the system. Refer to the
Troubleshooting
section in this manual if the power supply is plugged in, but the green light is
not illuminated.
– To reduce the risk of serious injury:
• Do not attempt to disassemble or service the pump or motor; no serviceable parts are
inside. Contact your La-Z-Boy
®
dealer for service.
• Check the condition of the power supplies, electrical cords, plugs, and connectors
monthly. Keep the power supplies and electrical cords away from heat sources.
Never operate the unit with a damaged power supply, electrical cord, plug, or connector.
Contact your La-Z-Boy
®
dealer for service.
• The 1PL, 1PM and 1PH lift chairs are intended for a single occupant, not exceeding 350
pounds. Do not operate the chair with more than one occupant in or on any part of the chair.
WARNING
Troubleshooting for Legrest Operation
If the legrest stops moving while closing, and all other functionality of the lift chair is operating,
the legrest may have encountered an obstruction.
1.
Check to make sure there are no obstructions. Lift and hold the legrest up, look for obstructions
and remove them.
2.
The legrest uses spring tension to close, and will close quickly when the obstruction is
removed and the legrest is released. Release the legrest slowly to prevent it from slamming shut.
If there are no obstructions and the legrest still does not close properly, contact your La-Z-Boy
®
dealer for service.
Troubleshooting for Lift and Recline Operation
If the lift or recline features do not work, check the following:
1.
Make sure the 120 volt power cord is plugged into an electrical outlet.
2.
Check the power supply to make sure the green LED power indicator light is on.
3.
Make sure the electrical outlet is working. For example, make sure there are no blown
fuses or tripped circuit breakers.
4.
Make sure all the connections are secure; refer to the
Assembly Instructions
.
5.
Make sure the electrical cords are not crimped or pinched. Make sure the electric
cord or plug is not damaged.
6.
Make sure the operating capacity has not been exceeded and there is only one
occupant in the chair; refer to the
Operating Instructions
.
Platinum Luxury-Lift
®
Troubleshooting
(Troubleshooting Continued)
27
26