Preparing Panels for Operation
6.
On startup all LBP Panels show the same device information on the first 6 buttons:
Device Monitor, Firmware Version, Panel ID, IP Address and MAC Address.
If the device has no physical link to the network, it will show “no network” status below the IP Address.
Thus there are no rotary hex encoders on the rear side of the device to configure the Panel ID, a long press on the
Panel ID button will switch to a Panel ID configuration screen as long the device is not connected to any
vsmStudio.
All Lawo devices will be shipped with DHCP enabled network configuration. If you don’t have a DHCP network ask
your administrator for static network settings and edit the “Network” section if required.
Do the following settings in VSM Discover:
Press “Apply” button in vsmDiscover if you are sure you have entered the settings correctly. The device will
automatically perform a reboot to apply the network configuration.
To connect the device to vsmStudio edit the Server 1 - 4 and Panel ID in the “Application” section. There is also a
possibility to connect an external serial device like an ENC17 or a RF-ID-Tag Reader. Please use the “Option:
External Encoder” or “Option: RFID” field to enable this feature. A software reset is necessary for proper working
external serial interface. Additional information can be found at VSM-LBP Accessories User Manual.
The Location and Comment fields in the “Misc” section can be set to easily allocate the device in your
environment.
Additional read-only status and device information from vsmDiscover: