LAWO vsm LBP User Manual Download Page 1

vsm LCD Button Panels

User Manual

Version: 4.0/1

To obtain the latest documentation and software downloads, please visit:

www.lawo.com/downloads

Edition: 31 March 2017

Copyright

All rights reserved. Permission to reprint or electronically reproduce any document or graphic in whole or in part
for any reason is expressly prohibited, unless prior written consent is obtained from the Lawo AG.

All trademarks and registered trademarks belong to their respective owners. It cannot be guaranteed that all
product names, products, trademarks, requisitions, regulations, guidelines, specifications and norms are free from
trade mark rights of third parties.

All entries in this document have been thoroughly checked; however no guarantee for correctness can be given.
Lawo AG cannot be held responsible for any misleading or incorrect information provided throughout this manual.

Lawo AG reserves the right to change specifications at any time without notice.

© Lawo AG, 2017

Version

Edition

Changes

Firm w are Version

1

2014-05-20

Initial draft

2.40

2

2014-06-13

Initial Release

2.40

3

2014-08-27

LBP 51 Pow er Consumption corrected

2.40

4.0/1

2017-03-31

New  Overview  graphics & template

2.46

Revision History

Summary of Contents for vsm LBP

Page 1: ...all product names products trademarks requisitions regulations guidelines specifications and norms are free from trade mark rights of third parties All entries in this document have been thoroughly ch...

Page 2: ...3 Introduction 6 4 Overview 7 E3 Buttons 7 4 1 NKK Buttons 12 4 2 LBP Accessories 13 4 3 5 Operating Conditions 14 6 Preparing Panels for Operation 15 7 Preparing Accessories for Operation 16 8 Techni...

Page 3: ...figuration and administration tool plus other software components vsmPanel vsmWebPanel vsmTimeSync etc vsm Gear User Manuals more about other hardware panel and interface options All Lawo manuals are...

Page 4: ...rve the temperature range and humidity specified in the installation instructions Do NOT expose devices to liquids which may drip or splash Do NOT place objects filled with liquids such as vases upon...

Page 5: ...tailed description of the fault We would like to remind you to please check carefully whether the failure is caused by erroneous configuration operation or connection before sending parts for repair P...

Page 6: ...stripe with 17 rotary encoders or an RFID Tag Reader box can be connected through the RS422 port of each LBP panel All panels are to be powered by an external capsulated 12Volts DC stabilized power s...

Page 7: ...ndensing humidity LBP 17 Number of buttons 17 LCD Buttons E3 R G B Backlight Options VSM SNAP Communication port 1xEthernet Dimensions 483mm x 43 7mm x 53 1mm WxHxD 1RU Weight approx 1 0KG Power Consu...

Page 8: ...midity LBP 32 Number of buttons 32 LCD Buttons E3 R G B Backlight Options VSM SNAP Communication port 1xEthernet Dimensions 240mm x 111 5mm x 53mm WxHxD 2 5RU 2 Weight approx 1 0KG Power Consumption 6...

Page 9: ...umidity LBP 34 Number of buttons 34 LCD Buttons E3 R G B Backlight Options VSM SNAP Communication port 1xEthernet Dimensions 483mm x 88mm x 53 2mm WxHxD 2RU Weight approx 1 4KG Power Consumption 6 5W...

Page 10: ...Number of buttons 50 LCD Buttons E3 R G B Backlight 1 Encoder Options Communication port 1xEthernet Dimensions 483mm x 88mm x 68 3mm WxHxD 2RU Weight approx 1 7KG Power Consumption 8 5W 12VDC 0 71A ma...

Page 11: ...g humidity LBP 39V vertical Number of buttons 39 LCD Buttons E3 R G B Backlight Options Communication port 1xEthernet Dimensions 92mm x 355 50mm x 59mm WxHxD Weight approx 1 3KG Power Consumption 7 2W...

Page 12: ...sing humidity LBP 41e Number of buttons 42 LCD Buttons NKK R G B Backlight 1 Encoder Options Communication port 1xEthernet Dimensions 483mm x 43 7mm x 69 3mm WxHxD 1RU Weight approx 1 8KG Power Consum...

Page 13: ...nel using RS422 via the RJ45 connectors on the rear of the LBP panel ENC 17 Number of Encoder 17 incremental encoder R G B Backlight Communication port RS422 communication to LBP panel only Dimensions...

Page 14: ...alfunction of the whole device Spillage of any liquids e g coffee coke water onto into the device may cause damage The storage temperature of the device must be within 20 C to 60 C with a maximum of 7...

Page 15: ...our administrator for static network settings and edit the Network section if required Do the following settings in VSM Discover Press Apply button in vsmDiscover if you are sure you have entered the...

Page 16: ...he corresponding LBP panel to enable this feature A software reset is necessary for proper working external serial interface A powered and connected ENC 17 device will pulse blue on each encoder once...

Page 17: ...internal I O voltage OK 5 Orange Blinks physical LAN connection TCP IP data transfer 8 1 2 ENC 17 Rear view 1 Orange Blinks receiving data from LBP panel 2 Yellow Blinks transmitting data to LBP pane...

Page 18: ...acing of LBP panel is X x Y 20 32mm x 19 05mm 8 3 Connectors LBP Panels 8 3 1 Power Connector for 12 V DC supply 4 Pin connector MC 1 5 4 STF 3 81 locked with two screws Mounted on power supply delive...

Page 19: ...led O2 O1 I2 I1 I_______I I_______I I_______I I_______I Dry Dry Input Gnd Input Gnd Relay Relay 0 12VDC 0 12VDC OUT No 2 OUT No 1 IN No 2 IN No 1 This Interface is a small signal interface only To avo...

Page 20: ...of RJ 45 plugs to touch ground flange of RJ 45 connectors Wrong wiring wrong cables wrong use of twisted pair and non shielded traces lead to short working distances Bad connection at one of the core...

Page 21: ...1 locked with two screws It is understood that if NOT using the original Power Supply Unit you need to make sure that there is only one single 12V DC supply with a maximum tolerance of 3 within the 12...

Page 22: ...d standard shielded network cable CAT5 or higher standard To avoid potential difference between devices shielded cable and shielded plugs with ground potential on both sides should be used Metalized p...

Page 23: ...an the button front of LBP panels is to use a soft cloth and smooth window cleaner fluid Do not expose the window cleaner directly to the buttons but to the cloth and then wipe softly over LBP panel f...

Reviews: